Inter-rater Reliability of Two-point Discrimination in Acute Stroke Patients
Overview
Rehabilitation Medicine
Authors
Affiliations
Background: The two-point discrimination (2PD) test is widely used in clinical practice to assess tactile acuity and central somatosensory function in stroke patients.
Objectives: The aim of this study was to evaluate the reliability of 2PD test in fingers on the affected and non-affected sides in acute stroke patients.
Methods: This was a single group repeated-measures inter-rater reliability study. Thirty adults with completed ischemic stroke and left paresis participated in the study. Static 2PD sensation was assessed using a standardized Dellon discriminator. Two examiners performed measurements of 2PD sensation on both hands. Each examiner made three series of measurements at intervals of 1 minute. After 15 minutes, the study was conducted in the same order by a second examiner.
Results: The ability for 2PD sensation was significantly reduced in all examined fingers on the affected side in comparison to the non-affected side. The difference was statistically significant (in each case, p < 0.0001). Inter-rater reliability (ICC2,1) for the first measurement at the affected site ranged from 0.95 to 0.98; at the non-affected site ranged from 0.30 to 0.82. Analysis of the average value of three measurements (ICC2,3) yielded values for the affected site ranging from 0.98 to 0.99; at the non-affected site ranged from 0.81 to 0.95.
Conclusions: The 2PD sensation values for all fingers were higher for the affected site in comparison to the non-affected site. Conducting three repeatable measurements ensures measurement reliability and repeatability when evaluating 2PD sensation in fingers on both sides in acute stroke patients.
Hu X, Hou X, Wang L J Exerc Sci Fit. 2025; 23(1):21-31.
PMID: 39758855 PMC: 11699271. DOI: 10.1016/j.jesf.2024.12.002.
Liu Y, Ma J, Li H, Shi W, Xiao Z, Yang Q Front Neurosci. 2023; 16:1065629.
PMID: 36711129 PMC: 9875544. DOI: 10.3389/fnins.2022.1065629.
Wolny T, Glibov K, Granek A, Linek P Sensors (Basel). 2023; 23(1).
PMID: 36617093 PMC: 9824188. DOI: 10.3390/s23010501.
Wolny T, Fernandez-de-Las Penas C, Granek A, Linek P Diagnostics (Basel). 2022; 12(10).
PMID: 36292036 PMC: 9600230. DOI: 10.3390/diagnostics12102347.
Two-point discrimination assessment of the upper extremities of healthy young Turkish individuals.
Ercalik C, Ozkurt S Turk J Phys Med Rehabil. 2022; 68(1):136-141.
PMID: 35949974 PMC: 9305636. DOI: 10.5606/tftrd.2022.6263.