» Articles » PMID: 28497070

Impact of Polyethylene Glycol 400/propylene Glycol/hydroxypropyl-guar and 0.1% Sodium Hyaluronate on Postoperative Discomfort Following Cataract Extraction Surgery: a Comparative Study

Overview
Journal Eye Vis (Lond)
Publisher Biomed Central
Specialty Ophthalmology
Date 2017 May 13
PMID 28497070
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Universal postoperative guidelines for cataract extraction surgery are yet to be introduced. Artificial tears are gaining popularity as an additional integral component of the postoperative regime. The primary objective of this study was to explore the impact of two prevalent artificial tear preparations on postoperative discomfort following cataract extraction surgery.

Methods: A total of 180 patients that underwent cataract extraction surgery were randomly divided into three groups according to their postoperative regime: a) Study group 1 (SG1) received a fixed combination of tobramycin and dexamethasone (FCTD) quid for 3 weeks and, additionally polyethylene glycol 400/propylene glycol/hydroxypropyl-guar quid, for 6 weeks, b) Study group 2 (SG2) received FCTD quid for 3 weeks and, additionally 0.1% sodium hyaluronate provided in the COMOD® device quid, for 6 weeks, and, c) Control Group (CG) received only FCTD quid for 3 weeks. The following indexes were evaluated at three postoperative checkpoints: 1) Subjective discomfort index (SDI) derived from four direct 10-scale Likert-type questions that were addressed to the patient and pertained to: a) foreign body sensation (FBS), b) blinking discomfort (BD), c) stinging sensation (SS), d) tearing sensation (TS), 2) Tear break-up time (TBUT), 3) Central corneal thickness (CCT) and, 4) Central Corneal Sensitivity (CCS).

Results: Both groups showed increased CCT values at the first examination point and reduced CCS values at all examination points. Furthermore, both SGs had better TBUT times at all examination points compared to CG (CG: 8.86 ± 1.08, SG1: 9.59 ± 1.45, CG2: 9.45 ± 1.33,  < 0.05). BD was significantly better in both SGs only at the 1 week of examination, while SDI values were better until the 3 week and only borderline better at 6 week. Lastly, no significant differences were detected between SGs, regarding all parameters, at all examination points.

Conclusion: Polyethylene glycol 400/propylene glycol/hydroxypropyl-guar and 0.1% sodium hyaluronate provided in the COMOD® device seem to be equally efficient in alleviating OSD symptoms following cataract extraction surgery and any of them should be routinely added to the postoperative regime.

Trial Registration: ClinicalTrials.gov Identifier: https://clinicaltrials.gov/ct2/show/NCT02558218NCT02558218.

Citing Articles

A Preservative-Free Approach - Effects on Dry Eye Signs and Symptoms After Cataract Surgery.

Jensen P, Nilsen C, Gundersen M, Gundersen K, Potvin R, Gazerani P Clin Ophthalmol. 2024; 18:591-604.

PMID: 38435373 PMC: 10906276. DOI: 10.2147/OPTH.S446804.


A Decade of Effective Dry Eye Disease Management with Systane Ultra (Polyethylene Glycol/Propylene Glycol with Hydroxypropyl Guar) Lubricant Eye Drops.

Srinivasan S, Manoj V Clin Ophthalmol. 2021; 15:2421-2435.

PMID: 34135570 PMC: 8200152. DOI: 10.2147/OPTH.S294427.


Protecting the Ocular Surface in Cataract Surgery: The Efficacy of the Perioperative Use of a Hydroxypropyl Guar and Hyaluronic Acid Ophthalmic Solution.

Favuzza E, Cennamo M, Vicchio L, Giansanti F, Mencucci R Clin Ophthalmol. 2020; 14:1769-1775.

PMID: 32616996 PMC: 7326168. DOI: 10.2147/OPTH.S259704.


Impact of 0.1% sodium hyaluronate and 0.2% sodium hyaluronate artificial tears on postoperative discomfort following cataract extraction surgery: a comparative study.

Ntonti P, Panagiotopoulou E, Karastatiras G, Breyannis N, Tsironi S, Labiris G Eye Vis (Lond). 2019; 6:6.

PMID: 30805405 PMC: 6373058. DOI: 10.1186/s40662-019-0131-8.

References
1.
Pascolini D, Mariotti S . Global estimates of visual impairment: 2010. Br J Ophthalmol. 2011; 96(5):614-8. DOI: 10.1136/bjophthalmol-2011-300539. View

2.
Li X, Hu L, Hu J, Wang W . Investigation of dry eye disease and analysis of the pathogenic factors in patients after cataract surgery. Cornea. 2007; 26(9 Suppl 1):S16-20. DOI: 10.1097/ICO.0b013e31812f67ca. View

3.
Labiris G, Sideroudi H, Rousopoulos K, Kozobolis V . Cohesive versus dispersive-cohesive ophthalmic viscosurgical device in torsional intelligent phaco. J Cataract Refract Surg. 2015; 41(3):681-2. DOI: 10.1016/j.jcrs.2015.01.010. View

4.
Guillon M, Maissa C, Ho S . Evaluation of the effects on conjunctival tissues of Optive eyedrops over one month usage. Cont Lens Anterior Eye. 2010; 33(2):93-9. DOI: 10.1016/j.clae.2010.01.007. View

5.
Maxwell W, Reiser H, Stewart R, Cavanagh H, Walters T, Sager D . Nepafenac dosing frequency for ocular pain and inflammation associated with cataract surgery. J Ocul Pharmacol Ther. 2008; 24(6):593-9. DOI: 10.1089/jop.2008.0023. View