» Articles » PMID: 28476318

Determination of Glyphosate in Soil/sludge by High Performance Liquid Chromatography

Overview
Journal J Chromatogr A
Publisher Elsevier
Specialty Chemistry
Date 2017 May 7
PMID 28476318
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

In order to evaluate the pollution caused due to glyphosate (Glyp) in soils and sludge, it is important to establish a set of standard determination techniques. In this work, the previously reported HPLC analytical method for determination of Glyp has been improved in order to be applied for all kinds of soils/sludge. The soil/sludge samples were extracted using sodium phosphate and trisodium citrate aqueous solutions. The extract was adjusted to pH 9 and contaminations were removed by washing with n-hexane. The method developed in this work further involves derivatization with 9-fluorenylmethylchloroformate (FMOC-Cl) followed by high performance liquid chromatography (HPLC) coupled with fluorescence detection. The method was validated in three soil (red soil, black soil and paddy soil) and two sludge samples (lake and river sludge) from China and verified in six laboratories. A good linear relationship (correlation coefficients ≥0.999) was observed within the range of 0.005-0.5mg/L. The limit of detection (LOD) and the limit of quantitation (LOQ) were determined to be 0.01mg/kg and 0.04mg/kg, respectively. The precision and accuracy were satisfactory with the relative standard deviation (RSD) lower than 15% and the mean recovery values ranging from 75% to 110% (n=6), that spiked at three levels (0.1, 0.5 and 1.0mg/kg).

Citing Articles

Pesticide Residues, Glyphosate Adsorption and Degradation Characteristics in Ethiopian Agricultural Soils.

Ayenew B, Getu E Environ Health Insights. 2025; 19:11786302241311679.

PMID: 39759479 PMC: 11700414. DOI: 10.1177/11786302241311679.


Ratiometric fluorescence probe based on boric acid-modified carbon dots and alizarin red for sensitive and rapid detection of glyphosate.

Yang J, Wang X, Yu Y, Cao Y, Guo M, Hu X Mikrochim Acta. 2024; 191(11):661.

PMID: 39387990 DOI: 10.1007/s00604-024-06748-9.


Electrochemical Detection of Glyphosate in Surface Water Samples Based on Modified Screen-Printed Electrodes.

Geana E, Ciucure C, Soare A, Enache S, Ionete R, Dinu L Nanomaterials (Basel). 2024; 14(11).

PMID: 38869573 PMC: 11173875. DOI: 10.3390/nano14110948.


Chromatographic Methods for the Determination of Glyphosate in Cereals Together with a Discussion of Its Occurrence, Accumulation, Fate, Degradation, and Regulatory Status.

Masci M, Caproni R, Nevigato T Methods Protoc. 2024; 7(3).

PMID: 38804332 PMC: 11130892. DOI: 10.3390/mps7030038.


Glyphosate Separating and Sensing for Precision Agriculture and Environmental Protection in the Era of Smart Materials.

Mazuryk J, Klepacka K, Kutner W, Sharma P Environ Sci Technol. 2023; 57(27):9898-9924.

PMID: 37384557 PMC: 10339735. DOI: 10.1021/acs.est.3c01269.