Evaluation of the Marginal Fit of CAD-CAM Zirconia Copings: Comparison of 2D and 3D Measurement Methods

Overview
Journal J Prosthet Dent
Specialty Dentistry
Date 2017 May 3
PMID 28461045
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The purpose of this in vitro study was to compare the marginal fit of zirconia copings by using 2 different measurement methods: a triple optical scan method and a silicone replica method.

Material And Methods: Sixty zirconia copings fabricated by computer-aided design and computer-aided manufacture (CAD-CAM) systems were studied for the marginal fit. For the replica method, the thickness of the light-body silicone layer of the discrepancy was assessed using light microscopy and image analysis software. The triple-scan optical method was performed to obtain a digital three-dimensional map of the marginal fit and analyzed marginal fit measurement values. For each method, the reliability of the measurement was tested, and a nonparametric analysis was then performed to compare the marginal fit values as measured by the 2 evaluation methods (α=.05).

Results: Intraclass correlation coefficients and repeatability coefficients revealed good repeatability for both of the evaluation methods. However, the triple-scan method produced a smaller marginal fit than the replica method (P<.001) for the entire group studied.

Conclusions: Although both methods showed good repeatability, the triple-scan method was more reliable.

Citing Articles

Fit accuracy and fracture resistance evaluation of advanced lithium disilicate crowns (in- vitro study).

Fayed A, Azer A, AboElHassan R BMC Oral Health. 2025; 25(1):58.

PMID: 39799312 PMC: 11725217. DOI: 10.1186/s12903-024-05325-z.


Does the choice of the measuring technique affect the comparison of fit between zirconia and cobalt-chromium prostheses?.

Daou E, Salameh P J Indian Prosthodont Soc. 2024; 24(2):201-207.

PMID: 38650346 PMC: 11129817. DOI: 10.4103/jips.jips_429_23.


SEM Evaluation of the Marginal Gap of Zirconia-Reinforced Lithium Silicate Full Crowns and the Effect of Post Crystallization: An In Vitro Study.

Shely A, Lugassy D, Anufriev M, Nissan J, Rauchwerger O, Ben-Izhack G Dent J (Basel). 2024; 12(3).

PMID: 38534285 PMC: 10969533. DOI: 10.3390/dj12030061.


Comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials - an in vitro study.

Nagi N, Fouda A, Bourauel C BMC Oral Health. 2023; 23(1):207.

PMID: 37029396 PMC: 10082505. DOI: 10.1186/s12903-023-02857-8.


Comparison of the marginal accuracy of metal copings fabricated by 3D-printed resin and milled polymethyl methacrylate - An study.

Arora O, Ahmed N, Maiti S J Adv Pharm Technol Res. 2023; 13(Suppl 1):S238-S242.

PMID: 36643161 PMC: 9836134. DOI: 10.4103/japtr.japtr_210_22.