A New "twist" on Right Heart Failure with Left Ventricular Assist Systems

Overview
Publisher Elsevier
Date 2017 Apr 19
PMID 28416103
Citations 31
Authors
Affiliations
Soon will be listed here.
Abstract

Despite significant efforts to predict and prevent right heart failure, it remains a leading cause of morbidity and mortality after implantation of left ventricular assist systems (LVAS). In this Perspective, we review the underappreciated anatomic and physiologic principles that govern the relationship between left and right heart function and contribute to this phenomenon. This includes the importance of considering the right ventricle (RV) and pulmonary arterial circuit as a coupled system; the contribution of the left ventricle (LV) to RV contractile function and the potential negative impact of acutely unloading the LV; the influence of the pericardium and ventricular twist on septal function; the role of RV deformation in reduced mechanical efficiency after device placement; and the potential of ongoing stressors of an elevated right-sided preload. We believe an appreciation of these complex issues is required to fully understand the expression of the unique phenotypes of right heart failure after LVAS implantation and for developing better prognostic and therapeutic strategies.

Citing Articles

Management of Pulmonary Hypertension in Patients on Left Ventricular Assist Device Support.

Salem M, Al-Saffar F, Hall S Rev Cardiovasc Med. 2024; 23(9):308.

PMID: 39077707 PMC: 11262404. DOI: 10.31083/j.rcm2309308.


Association between pulmonary artery pulsatility and mortality after implantation of left ventricular assist device.

Akamkam A, Galand V, Jungling M, Delmas C, Dambrin C, Pernot M ESC Heart Fail. 2024; 11(4):2100-2112.

PMID: 38581135 PMC: 11287349. DOI: 10.1002/ehf2.14716.


Foreword.

Interv Cardiol. 2024; 19:3.

PMID: 38532945 PMC: 10964287. DOI: 10.15420/icr.2024.19.S1.


Occult right ventricular dysfunction and right ventricular-vascular uncoupling in left ventricular assist device recipients.

Scheel III P, Cubero Salazar I, Friedman S, Haber L, Mukherjee M, Kauffman M J Heart Lung Transplant. 2023; 43(4):594-603.

PMID: 38036276 PMC: 10947813. DOI: 10.1016/j.healun.2023.11.015.


Hemodynamic Evaluation of Asynchronous Speed Modulation of a Continuous-Flow Left Ventricular Assist Device in an Acute-Myocardial Injury Sheep Model.

Tanaka S, Nishinaka T, Umeki A, Murakami T, Imaoka S, Mizuno T Ann Biomed Eng. 2023; 52(2):364-375.

PMID: 37851145 DOI: 10.1007/s10439-023-03383-y.