» Articles » PMID: 28409100

Arthroscopic Technique for Treatment of Schatzker Type III Tibia Plateau Fractures Without Fluoroscopy

Overview
Journal Arthrosc Tech
Publisher Elsevier
Date 2017 Apr 15
PMID 28409100
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Accurate reduction and maintenance of the stability with correct implant positioning is critical for surgical treatment of tibial plateau fractures. Our technique includes an arthroscopic reduction and fixation of Schatzker type III tibial plateau fractures with a bulls-eye screw placement without fluoroscopy control. With the arthroscopic guidance, an anterior cruciate ligament drill guide is placed and a K-wire sent to the midpoint of the depressed fragment through the guide at a 40° angle to the coronal axis of the tibia. A tunnel is created with the drill over the K-wire. The depressed fragment is further augmented with gentle impacts over the K-wire. After arthroscopic reduction control, an appropriate-sized iliac graft is pushed until it is below the depressed fragment. The targeting device is adjusted at 130° so that it is parallel to the joint line and a K-wire sent through the device so that it would pass just below the graft. The graft is then supported with cannulated screws sent over the K-wire. This technique provides an arthroscopic reduction of the chondral surface and precise placement of the rafting screws without fluoroscopy.

Citing Articles

Arthroscopy-Assisted Management of Schatzker Type III Lateral Tibial Plateau Fracture With Interference Screw Fixation.

Hermanowicz K, Mrozek T, Goralczyk A, Malinowski K Arthrosc Tech. 2021; 10(5):e1197-e1202.

PMID: 34141531 PMC: 8185522. DOI: 10.1016/j.eats.2021.01.014.


Arthroscopic-assisted reduction and fixation of proximal tibial fractures: personal surgical technique.

Compagnoni R, Maione A, Calanna F, Ferrua P, Randelli P Acta Biomed. 2021; 92(2):e2021066.

PMID: 33988160 PMC: 8182610. DOI: 10.23750/abm.v92i2.10711.


Arthroscopic Controlled Closed Reduction and Percutaneous Fixation of Posterolateral Tibia Plateau Impression Fractures.

Ackermann C, Frings J, Alm L, Frosch K Arthrosc Tech. 2019; 8(8):e867-e874.

PMID: 31700782 PMC: 6823802. DOI: 10.1016/j.eats.2019.04.001.


All-Arthroscopic Treatment of Schatzker Type III Lateral Tibial Plateau Fracture Without Fluoroscopy.

Hermanowicz K, Malinowski K, Goralczyk A, Guszczyn T, LaPrade R, Sadlik B Arthrosc Tech. 2019; 8(6):e567-e574.

PMID: 31334012 PMC: 6620739. DOI: 10.1016/j.eats.2019.01.021.

References
1.
Itokazu M, Matsunaga T . Arthroscopic restoration of depressed tibial plateau fractures using bone and hydroxyapatite grafts. Arthroscopy. 1993; 9(1):103-8. DOI: 10.1016/s0749-8063(05)80353-6. View

2.
Suganuma J, Akutsu S . Arthroscopically assisted treatment of tibial plateau fractures. Arthroscopy. 2004; 20(10):1084-9. DOI: 10.1016/j.arthro.2004.09.008. View

3.
Le Heron J, Padovani R, Smith I, Czarwinski R . Radiation protection of medical staff. Eur J Radiol. 2010; 76(1):20-3. DOI: 10.1016/j.ejrad.2010.06.034. View

4.
Yoon Y, Oh J, Oh C, Sahu D, Hwang J, Cho J . Inside out rafting K-wire technique for tibial plateau fractures. Arch Orthop Trauma Surg. 2011; 132(2):233-7. DOI: 10.1007/s00402-011-1409-z. View

5.
Beris A, Soucacos P, Glisson R, Seaber A, Urbaniak J . Load tolerance of tibial plateau depressions reinforced with a cluster of K-wires. Bull Hosp Jt Dis. 1996; 55(1):12-5. View