Abstract

Background: Limb length discrepancy (LLD) after total hip arthroplasty (THA) is a common problem which cannot be completely resolved. Many techniques have been described in order to minimize postoperative LLD, but most of these techniques are difficult to apply. Ideal technique must be simple and accurate. The most simple technique using a suture tied on the skin has well-known limitations, but its accuracy has not been evaluated before.

Materials And Methods: Sixty THAs in sixty patients (mean age 71 years, 1:1 male to female ratio) with hip osteoarthritis (37 cases in the right, and 23 cases in the left side) were studied in this prospective study. In all surgeries, the intraoperataive measurement of limb lengthening was performed using a suture tied on the skin of the lateral pelvis. The accuracy of this technique and correlation between intraoperative and postoperative radiological measurements of lengthening were evaluated.

Results: The mean preoperative LLD was -7.5 mm while the mean postoperative LLD was 1.58 mm. The accuracy of this technique, defined as the mean difference between the intraoperative and postoperative measurements was 1.8 mm. A strong correlation between these two measurements was noticed ( = 0.86).

Conclusion: The accuracy and correlation index of this simple technique were similar to those of other techniques. The studied technique is quite accurate when attention is given to certain details, such as the amount of tension applied on the suture, the position of the tied point on the skin, and the position of the leg during measurements.

Citing Articles

A Novel Approach for Correcting Limb Length Discrepancy in Total Hip Arthroplasty.

Kezer M, Kizilay Y Cureus. 2024; 16(3):e56628.

PMID: 38646251 PMC: 11032149. DOI: 10.7759/cureus.56628.


A novel method of manual positioning based on anatomical mark (shoulder-to-shoulder) to prevent postoperative leg-length discrepancy for femoral neck fractures in hip arthroplasty.

Zhang J, Zheng Y, Liu X, Xu Y, Fang Y, Lin Z Front Surg. 2022; 9:1030657.

PMID: 36386505 PMC: 9663648. DOI: 10.3389/fsurg.2022.1030657.


Accuracy of the Horizontal Calibrator in Correcting Leg Length and Restoring Femoral Offset in Total Hip Arthroplasty.

Chen X, Xing S, Zhu Z, Wang H, Yu Z, Bai X Front Surg. 2022; 9:845364.

PMID: 35310443 PMC: 8927056. DOI: 10.3389/fsurg.2022.845364.


Double-Stitch Technique: A Simple and Effective Method to Minimize Limb Length Discrepancy after Total Hip Arthroplasty.

Gupta R, Pathak P, Singh R, Majumdar K Indian J Orthop. 2019; 53(1):169-173.

PMID: 30905998 PMC: 6394180. DOI: 10.4103/ortho.IJOrtho_188_18.

References
1.
Halai M, Gupta S, Gilmour A, Bharadwaj R, Khan A, Holt G . The Exeter technique can lead to a lower incidence of leg-length discrepancy after total hip arthroplasty. Bone Joint J. 2015; 97-B(2):154-9. DOI: 10.1302/0301-620X.97B2.34530. View

2.
Wixson R, MacDonald M . Total hip arthroplasty through a minimal posterior approach using imageless computer-assisted hip navigation. J Arthroplasty. 2005; 20(7 Suppl 3):51-6. DOI: 10.1016/j.arth.2005.04.024. View

3.
Maloney W, Keeney J . Leg length discrepancy after total hip arthroplasty. J Arthroplasty. 2004; 19(4 Suppl 1):108-10. DOI: 10.1016/j.arth.2004.02.018. View

4.
Maratt J, Weber A, Knesek M, Lien J, Urquhart A . Novel method for ensuring leg length in total hip arthroplasty. Orthopedics. 2013; 36(4):e401-3. DOI: 10.3928/01477447-20130327-12. View

5.
Gonzalez Della Valle A, Slullitel G, Piccaluga F, Salvati E . The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty. 2005; 20(1):51-8. DOI: 10.1016/j.arth.2004.04.016. View