» Articles » PMID: 28392492

Pulse Sequences and Parallel Imaging for High Spatiotemporal Resolution MRI at Ultra-high Field

Overview
Journal Neuroimage
Specialty Radiology
Date 2017 Apr 11
PMID 28392492
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

The SNR and CNR benefits of ultra-high field (UHF) have helped push the envelope of achievable spatial resolution in MRI. For applications based on susceptibility contrast where there is a large CNR gain, high quality sub-millimeter resolution imaging is now being routinely performed, particularly in fMRI and phase imaging/QSM. This has enabled the study of structure and function of very fine-scale structures in the brain. UHF has also helped push the spatial resolution of many other MRI applications as will be outlined in this review. However, this push in resolution comes at a cost of a large encoding burden leading to very lengthy scans. Developments in parallel imaging with controlled aliasing and the move away from 2D slice-by-slice imaging to much more SNR-efficient simultaneous multi-slice (SMS) and 3D acquisitions have helped address this issue. In particular, these developments have revolutionized the efficiency of UHF MRI to enable high spatiotemporal resolution imaging at an order of magnitude faster acquisition. In addition to describing the main approaches to these techniques, this review will also outline important key practical considerations in using these methods in practice. Furthermore, new RF pulse design to tackle the B and SAR issues of UHF and the increased SAR and power requirement of SMS RF pulses will also be touched upon. Finally, an outlook into new developments of smart encoding in more dimensions, particularly through using better temporal/across-contrast encoding and reconstruction will be described. Just as controlled aliasing fully exploits spatial encoding in parallel imaging to provide large multiplicative gains in accelerations, the complimentary use of these new approaches in temporal and across-contrast encoding are expected to provide exciting opportunities for further large gains in efficiency to further push the spatiotemporal resolution of MRI.

Citing Articles

Micron-resolution Imaging of Cortical Bone under 14 T Ultrahigh Magnetic Field.

He T, Pang Z, Yin Y, Xue H, Pang Y, Song H Adv Sci (Weinh). 2023; 10(24):e2300959.

PMID: 37339792 PMC: 10460861. DOI: 10.1002/advs.202300959.


microRNA Biology on Brain Development and Neuroimaging Approach.

Tsujimura K, Shiohama T, Takahashi E Brain Sci. 2022; 12(10).

PMID: 36291300 PMC: 9599180. DOI: 10.3390/brainsci12101366.


The photobiology of the human circadian clock.

Schoonderwoerd R, de Rover M, Janse J, Hirschler L, Willemse C, Scholten L Proc Natl Acad Sci U S A. 2022; 119(13):e2118803119.

PMID: 35312355 PMC: 9060497. DOI: 10.1073/pnas.2118803119.


Mono-planar T-Hex: Speed and flexibility for high-resolution 3D imaging.

Engel M, Kasper L, Wilm B, Dietrich B, Patzig F, Vionnet L Magn Reson Med. 2021; 87(1):272-280.

PMID: 34398985 PMC: 9292510. DOI: 10.1002/mrm.28979.


TAPAS: An Open-Source Software Package for Translational Neuromodeling and Computational Psychiatry.

Frassle S, Aponte E, Bollmann S, Brodersen K, Do C, Harrison O Front Psychiatry. 2021; 12:680811.

PMID: 34149484 PMC: 8206497. DOI: 10.3389/fpsyt.2021.680811.


References
1.
Griswold M, Jakob P, Heidemann R, Nittka M, Jellus V, Wang J . Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med. 2002; 47(6):1202-10. DOI: 10.1002/mrm.10171. View

2.
Ugurbil K, Xu J, Auerbach E, Moeller S, Vu A, Duarte-Carvajalino J . Pushing spatial and temporal resolution for functional and diffusion MRI in the Human Connectome Project. Neuroimage. 2013; 80:80-104. PMC: 3740184. DOI: 10.1016/j.neuroimage.2013.05.012. View

3.
Bilgic B, Pfefferbaum A, Rohlfing T, Sullivan E, Adalsteinsson E . MRI estimates of brain iron concentration in normal aging using quantitative susceptibility mapping. Neuroimage. 2011; 59(3):2625-35. PMC: 3254708. DOI: 10.1016/j.neuroimage.2011.08.077. View

4.
Mooiweer R, Sbrizzi A, Raaijmakers A, van den Berg C, Luijten P, Hoogduin H . Combining a reduced field of excitation with SENSE-based parallel imaging for maximum imaging efficiency. Magn Reson Med. 2016; 78(1):88-96. PMC: 5484283. DOI: 10.1002/mrm.26346. View

5.
Duyn J, van Gelderen P, Li T, de Zwart J, Koretsky A, Fukunaga M . High-field MRI of brain cortical substructure based on signal phase. Proc Natl Acad Sci U S A. 2007; 104(28):11796-801. PMC: 1913877. DOI: 10.1073/pnas.0610821104. View