» Articles » PMID: 28356414

Prospective Evaluation of Light Scatter Technology Paired with Matrix-Assisted Laser Desorption IonizationTime of Flight Mass Spectrometry for Rapid Diagnosis of Urinary Tract Infections

Overview
Specialty Microbiology
Date 2017 Mar 31
PMID 28356414
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Urinary tract infections are one of the most common reasons for health care visits. Diagnosis and optimal treatment often require a urine culture, which takes an average of 1.5 to 2 days from urine collection to results, delaying optimal therapy. Faster, but accurate, alternatives are needed. Light scatter technology has been proposed for several years as a rapid screening tool, whereby negative specimens are excluded from culture. A commercially available light scatter device, BacterioScan 216Dx (BacterioScan, Inc.), has recently been advertised for this application. Paired use of mass spectrometry (MS) for bacterial identification and automated-system-based susceptibility testing straight from the light scatter suspension might provide dramatic improvement in times to a result. The present study prospectively evaluated the BacterioScan device, with culture as the reference standard. Positive light scatter specimens were used for downstream rapid matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) MS organism identification and automated-system-based antimicrobial susceptibility testing. Prospective evaluation of 439 urine samples showed a sensitivity of 96.5%, a specificity of 71.4%, and positive and negative predictive values of 45.1% and 98.8%, respectively. MALDI-TOF MS analysis of the suspension after density-based selection yielded a sensitivity of 72.1% and a specificity of 96.9%. Antimicrobial susceptibility testing of the samples identified by MALDI-TOF MS produced an overall categorical agreement of 99.2%. Given the high sensitivity and negative predictive value of results obtained, BacterioScan 216Dx is a reasonable approach for urine screening and might produce negative results in as few as 3 h, with no downstream workup. Paired rapid identification and susceptibility testing might be useful when MALDI-TOF MS results in an organism identification, and it might decrease the time to a result by more than 24 h.

Citing Articles

Novel technologies for the diagnosis of urinary tract infections.

Bermudez T, Schmitz J, Boswell M, Humphries R J Clin Microbiol. 2025; 63(2):e0030624.

PMID: 39760497 PMC: 11837515. DOI: 10.1128/jcm.00306-24.


Accuracy of molecular diagnostic techniques in patients with a confirmed urine culture: A systematic review and meta-analysis.

Robledo X, Arcila K, Riascos S, Garcia-Perdomo H Can Urol Assoc J. 2022; 16(9):E484-E489.

PMID: 35426783 PMC: 9484739. DOI: 10.5489/cuaj.7677.


Accuracy of matrix-assisted laser desorption ionization time-of-flight mass spectrometry for direct bacterial identification from culture-positive urine samples.

Sun B, Wang W, Ma P, Gu B Ann Transl Med. 2021; 9(8):647.

PMID: 33987345 PMC: 8106043. DOI: 10.21037/atm-20-7310.


Modern Tools for Rapid Diagnostics of Antimicrobial Resistance.

Vasala A, Hytonen V, Laitinen O Front Cell Infect Microbiol. 2020; 10:308.

PMID: 32760676 PMC: 7373752. DOI: 10.3389/fcimb.2020.00308.


Diagnostic Accuracy of MALDI-TOF Mass Spectrometry for the Direct Identification of Clinical Pathogens from Urine.

Tang M, Yang J, Li Y, Zhang L, Peng Y, Chen W Open Med (Wars). 2020; 15:266-273.

PMID: 32292823 PMC: 7147288. DOI: 10.1515/med-2020-0038.


References
1.
Doern C, Butler-Wu S . Emerging and Future Applications of Matrix-Assisted Laser Desorption Ionization Time-of-Flight (MALDI-TOF) Mass Spectrometry in the Clinical Microbiology Laboratory: A Report of the Association for Molecular Pathology. J Mol Diagn. 2016; 18(6):789-802. DOI: 10.1016/j.jmoldx.2016.07.007. View

2.
Hayden R, Clinton L, Hewitt C, Koyamatsu T, Sun Y, Jamison G . Rapid Antimicrobial Susceptibility Testing Using Forward Laser Light Scatter Technology. J Clin Microbiol. 2016; 54(11):2701-2706. PMC: 5078546. DOI: 10.1128/JCM.01475-16. View

3.
Falbo R, Sala M, Signorelli S, Venturi N, Signorini S, Brambilla P . Bacteriuria screening by automated whole-field-image-based microscopy reduces the number of necessary urine cultures. J Clin Microbiol. 2012; 50(4):1427-9. PMC: 3318571. DOI: 10.1128/JCM.06003-11. View

4.
Kim Y, Park K, Lee K, Park Y . Direct Identification of Urinary Tract Pathogens From Urine Samples Using the Vitek MS System Based on Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry. Ann Lab Med. 2015; 35(4):416-22. PMC: 4446580. DOI: 10.3343/alm.2015.35.4.416. View

5.
Monsen T, Ryden P . Flow cytometry analysis using sysmex UF-1000i classifies uropathogens based on bacterial, leukocyte, and erythrocyte counts in urine specimens among patients with urinary tract infections. J Clin Microbiol. 2014; 53(2):539-45. PMC: 4298542. DOI: 10.1128/JCM.01974-14. View