» Articles » PMID: 28335542

The Impact of Bending Stress on the Performance of Giant Magneto-Impedance (GMI) Magnetic Sensors

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2017 Mar 25
PMID 28335542
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

The flexibility of amorphous Giant Magneto-Impedance (GMI) micro wires makes them easy to use in several magnetic field sensing applications, such as electrical current sensing, where they need to be deformed in order to be aligned with the measured field. The present paper deals with the bending impact, as a parameter of influence of the sensor, on the GMI effect in 100 µm Co-rich amorphous wires. Changes in the values of key parameters associated with the GMI effect have been investigated under bending stress. These parameters included the GMI ratio, the intrinsic sensitivity, and the offset at a given bias field. The experimental results have shown that bending the wire resulted in a reduction of GMI ratio and sensitivity. The bending also induced a net change in the offset for the considered bending curvature and the set of used excitation parameters (1 MHz, 1 mA). Furthermore, the field of the maximum impedance, which is generally related to the anisotropy field of the wire, was increased. The reversibility and the repeatability of the bending effect were also evaluated by applying repetitive bending stresses. The observations have actually shown that the behavior of the wire under the bending stress was roughly reversible and repetitive.

Citing Articles

Spiral Annealing of Magnetic Microwires.

Chizhik A, Corte-Leon P, Zhukova V, Blanco J, Gonzalez J, Zhukov A Sensors (Basel). 2024; 24(19).

PMID: 39409279 PMC: 11478632. DOI: 10.3390/s24196239.


A Curvature Sensor Utilizing the Matteucci Effect in Amorphous Wire.

Alimohammadi S, Williams P, Meydan T Sensors (Basel). 2023; 23(3).

PMID: 36772284 PMC: 9921420. DOI: 10.3390/s23031243.


Modelling and Measurement of Magnetically Soft Nanowire Arrays for Sensor Applications.

Ripka P, Grim V, Mirzaei M, Hrakova D, Uhrig J, Emmerich F Sensors (Basel). 2020; 21(1).

PMID: 33374910 PMC: 7792604. DOI: 10.3390/s21010003.


Strain Dependence of Hysteretic Giant Magnetoimpedance Effect in Co-Based Amorphous Ribbon.

Nowicki M, Gazda P, Szewczyk R, Marusenkov A, Nosenko A, Kyrylchuk V Materials (Basel). 2019; 12(13).

PMID: 31262016 PMC: 6651656. DOI: 10.3390/ma12132110.


Effect of Torsion Stress on the Offset and Sensitivity of Diagonal and Off-Diagonal GMI in Amorphous Wires.

Nabias J, Asfour A, Yonnet J Sensors (Basel). 2018; 18(12).

PMID: 30477226 PMC: 6308677. DOI: 10.3390/s18124121.