» Articles » PMID: 28299489

A Split-face Comparison of Q-switched Nd:YAG 1064-nm Laser for Facial Rejuvenation in Nevus of Ota Patients

Overview
Journal Lasers Med Sci
Publisher Springer
Date 2017 Mar 17
PMID 28299489
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

We aimed to investigate the efficacy and safety of using the 1064-nm Q-switched neodymium-doped yttrium aluminum garnet (Nd:YAG) laser (QSNYL) for skin rejuvenation in patients with Nevus of Ota. A retrospective, randomized, split-faced, clinical study was conducted. Twenty-nine patients with unilateral moderate to severe Nevus of Ota were enrolled. The participants completed 3-13 sessions of QSNYL treatments 3-6 months apart. Two independent physicians compared the treated and untreated sides of the face to evaluate the clearance of Nevus of Ota, the wrinkle severity rating scale (WSRS), the global aesthetic improvement scale (GAIS), and adverse event reporting. Patients' satisfaction levels were also considered. Of the 29 patients, 28 (96.6%) achieved nearly complete pigmentation clearance. After an average of 7.76 ± 2.99 sessions, statistically significant improvement in wrinkles and skin texture were observed, compared with the untreated side. The degree of skin rejuvenation was positively correlated with the number of treatment sessions. No clinically adverse effects were observed. Repeated QSNYL treatments not only remove the pigment in Nevus of Ota effectively and safely but also improve facial rejuvenation.

Citing Articles

Pilot Study to Demonstrate Improvement in Skin Tone and Texture by Treatment with a 1064 nm Q-Switched Neodymium-Doped Yttrium Aluminum Garnet Laser.

Munavalli G, Leight-Dunn H J Clin Med. 2024; 13(5).

PMID: 38592205 PMC: 10931777. DOI: 10.3390/jcm13051380.


Efficacy of Fractional Carbon Dioxide (CO) Laser versus Q-Switched Neodymium-Doped Yttrium Aluminum Garnet (Nd:YAG) and Potassium-Titanyl-Phosphate (KTP) Lasers in the Treatment of Acanthosis Nigricans.

Elmasry M, Khalil M, Badawi A, Zaki N, Fahim A Clin Cosmet Investig Dermatol. 2023; 16:705-715.

PMID: 36992970 PMC: 10042172. DOI: 10.2147/CCID.S401479.


Comparing the efficacy and safety of Q-switched and picosecond lasers in the treatment of nevus of Ota: a systematic review and meta-analysis.

Williams N, Gurnani P, Long J, Reynolds J, Pan Y, Suzuki T Lasers Med Sci. 2020; 36(4):723-733.

PMID: 32839837 DOI: 10.1007/s10103-020-03125-9.

References
1.
Gold M, Sensing W, Biron J . Fractional Q-switched 1,064-nm laser for the treatment of photoaged-photodamaged skin. J Cosmet Laser Ther. 2013; 16(2):69-76. DOI: 10.3109/14764172.2013.864197. View

2.
Hong J, Park S, Seo K, Goo B, Hwang E, Park G . Long pulsed 1064 nm Nd:YAG laser treatment for wrinkle reduction and skin laxity: evaluation of new parameters. Int J Dermatol. 2014; 54(9):e345-50. DOI: 10.1111/ijd.12626. View

3.
Rho N, Kim W, Lee D, Yang J, Lee E, Lee J . Histopathological parameters determining lesion colours in the naevus of Ota: a morphometric study using computer-assisted image analysis. Br J Dermatol. 2004; 150(6):1148-53. DOI: 10.1111/j.1365-2133.2004.05902.x. View

4.
Felton S, Al-Niaimi F, Ferguson J, Madan V . Our perspective of the treatment of naevus of Ota with 1,064-, 755- and 532-nm wavelength lasers. Lasers Med Sci. 2013; 29(5):1745-9. DOI: 10.1007/s10103-013-1332-3. View

5.
Lee M, Hu S, Chen M, Shih Y, Huang Y, Lee S . Skin rejuvenation with 1,064-nm Q-switched Nd:YAG laser in Asian patients. Dermatol Surg. 2009; 35(6):929-32. DOI: 10.1111/j.1524-4725.2009.01157.x. View