» Articles » PMID: 28290224

Inpatient Continuous Glucose Monitoring and Glycemic Outcomes

Overview
Specialty Endocrinology
Date 2017 Mar 15
PMID 28290224
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Continuous glucose monitoring (CGM) is commonly used in the outpatient setting to improve diabetes management. CGM can provide real-time glucose trends, detecting hyperglycemia and hypoglycemia before the onset of clinical symptoms. In 2011, at the time the Endocrine Society CGM guidelines were published, the society did not recommend inpatient CGM as its efficacy and safety were unknown. While many studies have subsequently evaluated inpatient CGM accuracy and reliability, glycemic outcome studies have not been widely published. In the non-ICU setting, investigational CGM studies have commonly blinded providers and patients to glucose data. Retrospective review of the glucose data reflects increased hypoglycemia detection with CGM. In the ICU setting, data are inconsistent whether CGM can improve glycemic outcomes. Studies have not focused on hospitalized patients with type 1 diabetes mellitus, the population most likely to benefit from inpatient CGM. This article reviews inpatient CGM glycemic outcomes in the non-ICU and ICU setting.

Citing Articles

Composite Metric of Glycemic Control Q-Score Is Elevated in Pediatric and Adolescent/Young Adult Hematopoietic Stem Cell Transplant Recipients.

Cho S, Vigers T, Pyle L, Franklin A, Sopfe J, Jeney F Diabetes Technol Ther. 2022; 25(2):116-121.

PMID: 36511871 PMC: 9894599. DOI: 10.1089/dia.2022.0246.


Reliability of Inpatient CGM: Comparison to Standard of Care.

Price C, Ditton G, Russell G, Aloi J J Diabetes Sci Technol. 2021; 17(2):329-335.

PMID: 34911384 PMC: 10012376. DOI: 10.1177/19322968211062168.


Continuous glucose monitoring in the hospital: an update in the era of COVID-19.

Gothong C, Singh L, Satyarengga M, Spanakis E Curr Opin Endocrinol Diabetes Obes. 2021; 29(1):1-9.

PMID: 34845159 PMC: 8711300. DOI: 10.1097/MED.0000000000000693.


Consumer Wearables for Patient Monitoring in Otolaryngology: A State of the Art Review.

Somani S, Yu K, Chiu A, Sykes K, Villwock J Otolaryngol Head Neck Surg. 2021; 167(4):620-631.

PMID: 34813407 PMC: 10228711. DOI: 10.1177/01945998211061681.


Use of Continuous Glucose Monitoring in Non-ICU Hospital Settings for People With Diabetes: A Scoping Review of Emerging Benefits and Issues.

Clubbs Coldron B, Coates V, Khamis A, MacRury S J Diabetes Sci Technol. 2021; 17(2):467-473.

PMID: 34696622 PMC: 10012381. DOI: 10.1177/19322968211053652.


References
1.
Ballesteros D, Martinez O, Blancas Gomez-Casero R, Martin Parra C, Lopez Matamala B, Estebanez B . Continuous tissue glucose monitoring correlates with measurement of intermittent capillary glucose in patients with distributive shock. Med Intensiva. 2014; 39(7):405-11. DOI: 10.1016/j.medin.2014.09.004. View

2.
Joseph J, Torjman M, Strasma P . Vascular Glucose Sensor Symposium: Continuous Glucose Monitoring Systems (CGMS) for Hospitalized and Ambulatory Patients at Risk for Hyperglycemia, Hypoglycemia, and Glycemic Variability. J Diabetes Sci Technol. 2015; 9(4):725-38. PMC: 4525658. DOI: 10.1177/1932296815587938. View

3.
Goldberg P, Siegel M, Sherwin R, Halickman J, Lee M, Bailey V . Implementation of a safe and effective insulin infusion protocol in a medical intensive care unit. Diabetes Care. 2004; 27(2):461-7. DOI: 10.2337/diacare.27.2.461. View

4.
Scuffi C, Lucarelli F, Valgimigli F . Minimizing the impact of time lag variability on accuracy evaluation of continuous glucose monitoring systems. J Diabetes Sci Technol. 2013; 6(6):1383-91. PMC: 3570879. DOI: 10.1177/193229681200600618. View

5.
Wollersheim T, Engelhardt L, Pachulla J, Moergeli R, Koch S, Spies C . Accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: a prospective clinical trial. Ann Intensive Care. 2016; 6(1):70. PMC: 4954792. DOI: 10.1186/s13613-016-0167-z. View