Contrast Enhanced Ultrasound in CT-undetermined Focal Liver Lesions

Overview
Publisher Thieme
Date 2017 Mar 14
PMID 28286878
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose of this study was to examine the diagnostic accuracy of CEUS in the diagnosis of focal liver lesions, which were undetermined at CT scan. From January 2010 to December 2010, patients with CT-undetermined focal liver lesions were included in this study. A total of 78 patients were evaluated: 41 men and 37 women, mean age 61.8 years; age range 30-91 years. All patients were examined with GE LOGIQ 9E ultrasound scanners with contrast-specific software, and SonoVue intravenous bolus. The standard of reference was composite consisting of: percutaneous biopsy, surgical resection, PET/CT and clinical follow-up. The 78 included patients had 163 undetermined focal liver lesions, mean size 1.1 cm, range 0.1-5.3 cm. There were 18 malignant and 145 benign liver lesions, as defined by the standard of reference. In differentiating between benign vs. malignant CEUS demonstrated sensitivity, specificity, PPV, NPV and accuracy of 94.4% (95% CI: 56.3-99.5%), 99.3% (95% CI: 94.9 -99.9%), 94.4% (95% CI: 56.3-99.5%), 99.3% (95% CI: 94.9-99.9%) and 98.7% (95% CI: 94.9-99.7%), respectively. If the CEUS-inconclusive results were assumed to indicate malignancy, then sensitivity, specificity, PPV, NPV and accuracy would be 95.8% (95% CI: 66.4-99.6%), 98.6% (95% CI: 94.4-99.7%), 92.0% (95CI: 65.1-98.6%), 99.3% (95% CI: 95.0-99.9%), 98.2% (95% CI: 94.4-99.5%). The results of this study showed a high diagnostic accuracy for CEUS in undetermined focal liver lesions found by CT. Due to a high diagnostic accuracy of CEUS in this study, it was cautiously concluded that CEUS is useful in differentiating between malignant and benign focal liver lesions in clinical practice.

Citing Articles

Percutaneous ablation of liver metastases from colorectal cancer: a comparison between the outcomes of ultrasound guidance and CT guidance using propensity score matching.

Luo M, Peng S, Yang G, Lin L, Lu L, Chen J Ultrasonography. 2022; 42(1):54-64.

PMID: 36464955 PMC: 9816698. DOI: 10.14366/usg.21212.


Imaging Features of Hepatocellular Carcinoma in the Non-Cirrhotic Liver with Sonazoid-Enhanced Contrast-Enhanced Ultrasound.

Chen S, Qiu Y, Zuo D, Shi S, Wang W, Dong Y Diagnostics (Basel). 2022; 12(10).

PMID: 36291962 PMC: 9601233. DOI: 10.3390/diagnostics12102272.


Contrast-enhanced ultrasonography for the evaluation of malignant focal liver lesions.

Chammas M, Bordini A Ultrasonography. 2021; 41(1):4-24.

PMID: 34724777 PMC: 8696138. DOI: 10.14366/usg.21001.


Differentiation of atypical hepatic hemangioma from liver metastases: Diagnostic performance of a novel type of color contrast enhanced ultrasound.

Wu X, Bai X, Yang W, Sun Y, Wang H, Wu W World J Gastroenterol. 2020; 26(9):960-972.

PMID: 32206006 PMC: 7081006. DOI: 10.3748/wjg.v26.i9.960.


Comparative Diagnostic Accuracy of Contrast-Enhanced Ultrasound and Shear Wave Elastography in Differentiating Benign and Malignant Lesions: A Network Meta-Analysis.

Huang R, Jiang L, Xu Y, Gong Y, Ran H, Wang Z Front Oncol. 2019; 9:102.

PMID: 30891425 PMC: 6412152. DOI: 10.3389/fonc.2019.00102.

References
1.
Quaia E, Calliada F, Bertolotto M, Rossi S, Garioni L, Rosa L . Characterization of focal liver lesions with contrast-specific US modes and a sulfur hexafluoride-filled microbubble contrast agent: diagnostic performance and confidence. Radiology. 2004; 232(2):420-30. DOI: 10.1148/radiol.2322031401. View

2.
Volk M, Strotzer M, Lenhart M, Techert J, Seitz J, Feuerbach S . Frequency of benign hepatic lesions incidentally detected with contrast-enhanced thin-section portal venous phase spiral CT. Acta Radiol. 2001; 42(2):172-5. DOI: 10.1034/j.1600-0455.2001.042002172.x. View

3.
Quaia E, De Paoli L, Angileri R, Cabibbo B, Cova M . Indeterminate solid hepatic lesions identified on non-diagnostic contrast-enhanced computed tomography: assessment of the additional diagnostic value of contrast-enhanced ultrasound in the non-cirrhotic liver. Eur J Radiol. 2014; 83(3):456-62. DOI: 10.1016/j.ejrad.2013.12.012. View

4.
von Herbay A, Westendorff J, Gregor M . Contrast-enhanced ultrasound with SonoVue: differentiation between benign and malignant focal liver lesions in 317 patients. J Clin Ultrasound. 2009; 38(1):1-9. DOI: 10.1002/jcu.20626. View

5.
Correas J, Bridal L, Lesavre A, Mejean A, Claudon M, Helenon O . Ultrasound contrast agents: properties, principles of action, tolerance, and artifacts. Eur Radiol. 2001; 11(8):1316-28. DOI: 10.1007/s003300100940. View