Comparative Evaluation of Salivary Bisphenol A Levels in Patients Wearing Vacuum-formed and Hawley Retainers: An In-vivo Study

Overview
Publisher Elsevier
Specialty Dentistry
Date 2017 Mar 5
PMID 28257731
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: The aims of the study were to evaluate and compare the bisphenol A (BPA) levels in saliva in patients using vacuum-formed retainers or Hawley retainers.

Methods: Forty-five patients who had completed their fixed orthodontic treatment and were entering the retention phase were randomly allocated into 1 of 3 groups: vacuum-formed retainer, Hawley retainer fabricated by heat cure, and Hawley retainer fabricated by chemical cure. Saliva samples were collected immediately before placement, within 1 hour after placement, 1 week and 1 month after placement. Statistical analyses were performed by using 2-way analysis of variance and post-hoc multiple-comparisons Tukey HSD tests.

Results: Statistically significant BPA levels in saliva were found for all groups (P ≤0.05). The highest levels were noted in the vacuum-formed retainer group, followed by Hawley retainers fabricated by chemical cure; the lowest levels were found with Hawley retainers fabricated by heat cure.

Conclusions: With many options available for removable retainers, clinicians should consider the BPA release from these retainers; a Hawley retainer fabricated by heat cure is a favorable choice.

Citing Articles

Bisphenol A Release from Fiber-Reinforced vs. Conventional Stainless-Steel Fixed Retainers: An In Vitro Study.

Tsoukala E, Maragou N, Antonelaki A, Thomaidis N, Sifakakis I J Funct Biomater. 2025; 16(2).

PMID: 39997602 PMC: 11856908. DOI: 10.3390/jfb16020068.


Biological significance of long-term bisphenol A release in the saliva of patients wearing orthodontic appliances: A systematic review and meta-analysis.

Vitores-Calero A, Zamora-Martinez N, Bellot-Arcis C, Tarazona-Alvarez B, Montiel-Company J, Garcia-Sanz V J Clin Exp Dent. 2024; 16(7):e912-e920.

PMID: 39219830 PMC: 11360455. DOI: 10.4317/jced.61735.


Salivary levels of eluents during Invisalign™ treatment with attachments: an in vivo investigation.

Stocker L, Zervou S, Papageorgiou S, Karakousoglou S, Triantis T, Hiskia A Prog Orthod. 2024; 25(1):22.

PMID: 38825612 PMC: 11144685. DOI: 10.1186/s40510-024-00522-6.


analysis of the influence of the thermocycling and the applied force on orthodontic clear aligners.

Cintora-Lopez P, Arrieta-Blanco P, Martin-Vacas A, Paz-Cortes M, Gil J, Aragoneses J Front Bioeng Biotechnol. 2024; 11:1321495.

PMID: 38173871 PMC: 10761475. DOI: 10.3389/fbioe.2023.1321495.


Evaluation of bisphenol release of different clear aligner materials using the liquid chromatography-mass spectrometry/mass spectrometry method.

Cifci Ozkan E, Dumanli Gok G Angle Orthod. 2023; 93(6):721-726.

PMID: 37539687 PMC: 10633800. DOI: 10.2319/010923-17.1.