 To test the hypothesis that the incomplete diagnosis "iodine allergy" is a possibly dangerous concept for patients under routine radiologic conditions.  300 patients with a history of an "iodine allergy" were retrospectively screened and compared with two age-, sex-, and procedure-matched groups of patients either diagnosed with a nonspecific "iodine contrast medium (ICM) allergy" or an allergy to a specific ICM agent. For all groups, the clinical symptoms of the most recent past adverse drug reaction (ADR), prophylactic actions taken for subsequent imaging, and ultimate outcome were recorded and analyzed.  The diagnosis "iodine allergy" was not otherwise specified in 84.3 % patients. For this group, in most cases, the symptoms of the previous ADRs were not documented. In contrast, the type of ADR was undocumented in only a minority of patients in the comparison groups. In the group of patients with an "iodine allergy" the percentage of unenhanced CT scans was greater than within the other two groups (36.7 % vs. 28.7 %/18.6 %). ADRs following prophylactic measures were only observed in the "iodine allergy" group (OR of 9.24 95 % CI 1.16 - 73.45; p < 0.04).  This data confirms the hypothesis that the diagnosis "iodine allergy" is potentially dangerous and results in uncertainty in clinical management and sometimes even ineffective prophylactic measures.   · The term "iodine allergy" is imprecise, because it designates allergies against different substance classes, such as disinfectants with complexed iodine and contrast media containing covalently bound iodine.. · There is a clear correlation between the exactness of the diagnosis - from the alleged "iodine allergy" to "contrast media allergy" to naming the exact culprit CM - and the quality of documentation of the symptoms.. · Management of patients diagnosed with "iodine allergy" was associated with uncertainty leading to unenhanced scans and sometimes unnecessary prophylactic actions.. · The term "iodine allergy" should be omitted, because it is potentially dangerous and can decrease the quality of radiology exams.. · Böhm Ingrid, Nairz Knud, Morelli John N et al. Iodinated Contrast Media and the Alleged "Iodine Allergy": An Inexact Diagnosis Leading to Inferior Radiologic Management and Adverse Drug Reactions. Fortschr Röntgenstr 2017; 189: 326 - 332.

Citing Articles

Evaluation of Carotid Stenosis in a High-Stroke-Risk Population by Hemodynamic Dual-Parameters Based on Ultrasound Vector Flow Imaging.

Hong S, Dong Y, Gao W, Song D, Liu M, Li W Brain Behav. 2024; 14(11):e70150.

PMID: 39552116 PMC: 11570680. DOI: 10.1002/brb3.70150.


RadioComics-Santa Claus and the breakthrough reaction.

Lombardo P, Nairz K, Boehm I Insights Imaging. 2024; 15(1):251.

PMID: 39412605 PMC: 11484994. DOI: 10.1186/s13244-024-01835-0.


Immediate hypersensitivity reactions to iodinated contrast media despite drug prophylaxis-a comparative retrospective cohort study of breakthrough reactions in Bern (Switzerland) and Seoul (South Korea).

Beiner L, Jeong J, Kang D, Lombardo P, Kang H, Boehm I Quant Imaging Med Surg. 2024; 14(5):3326-3338.

PMID: 38720860 PMC: 11074757. DOI: 10.21037/qims-23-912.


Stratified assessment and warning regimen for prevention of acute adverse reactions to iodinated contrast media: results of 150,343 cases in a tertiary hospital.

Liu H, Qiu H, Liu J, Wang L, Zhao L, Wang Y Med Biol Eng Comput. 2023; 61(3):709-720.

PMID: 36595153 PMC: 9918562. DOI: 10.1007/s11517-022-02751-5.


To crack a nut with a sledgehammer: premedication in a patient with a history of mild symptoms following the injection of a contrast agent.

Boehm I Quant Imaging Med Surg. 2022; 12(7):4005-4006.

PMID: 35782240 PMC: 9246732. DOI: 10.21037/qims-22-256.