» Articles » PMID: 28238226

Dual-energy CT in Gout - A Review of Current Concepts and Applications

Overview
Date 2017 Feb 27
PMID 28238226
Citations 44
Authors
Affiliations
Soon will be listed here.
Abstract

Dual-energy computed tomography (DECT) is a relatively recent development in the imaging of gouty arthritis. Its availability and usage have become increasingly widespread in recent years. DECT is a non-invasive method for the visualisation, characterisation and quantification of monosodium urate crystal deposits which aids the clinician in the early diagnosis, treatment and follow-up of this condition. This article aims to give an up to date review and summary of existing literature on the role and accuracy of DECT in the imaging of gout. Techniques in image acquisition, processing and interpretation will be discussed along with pitfalls, artefacts and clinical applications.

Citing Articles

Imaging methods in monitoring gout - a pictorial essay.

Korzen M, Nowakowska-Plaza A, Leszkiewicz M, Sudol-Szopinska I J Ultrason. 2024; 24(97):1-6.

PMID: 39525601 PMC: 11546896. DOI: 10.15557/jou.2024.0022.


Dual-energy CT: Impact of detecting bone marrow oedema in occult trauma in the Emergency.

Ahmad M, Liu L, Sheikh A, Nicolaou S BJR Open. 2024; 6(1):tzae025.

PMID: 39345237 PMC: 11427222. DOI: 10.1093/bjro/tzae025.


Updates on the Applications of Spectral Computed Tomography for Musculoskeletal Imaging.

Eibschutz L, Matcuk G, Chiu M, Lu M, Gholamrezanezhad A Diagnostics (Basel). 2024; 14(7).

PMID: 38611645 PMC: 11011285. DOI: 10.3390/diagnostics14070732.


Imaging modalities for non-acute pathologies of the foot and ankle.

Papineni V, Mariathas M, Sidhu S, Chari B J Clin Orthop Trauma. 2024; 48:102329.

PMID: 38299021 PMC: 10826320. DOI: 10.1016/j.jcot.2023.102329.


Impact of Dual-Energy Computed Tomography (DECT) Postprocessing Protocols on Detection of Monosodium Urate (MSU) Deposits in Foot Tendons of Cadavers.

Klauser A, Strobl S, Schwabl C, Kremser C, Klotz W, Nikodinovska V Diagnostics (Basel). 2023; 13(13).

PMID: 37443602 PMC: 10341184. DOI: 10.3390/diagnostics13132208.


References
1.
Schwartz S . Disease of distinction. Explore (NY). 2006; 2(6):515-9. DOI: 10.1016/j.explore.2006.08.007. View

2.
Schlesinger N, Baker D, Schumacher Jr H . Serum urate during bouts of acute gouty arthritis. J Rheumatol. 1998; 24(11):2265-6. View

3.
Mallinson P, Reagan A, Coupal T, Munk P, Ouellette H, Nicolaou S . The distribution of urate deposition within the extremities in gout: a review of 148 dual-energy CT cases. Skeletal Radiol. 2013; 43(3):277-81. DOI: 10.1007/s00256-013-1771-8. View

4.
Johnson T . Dual-energy CT: general principles. AJR Am J Roentgenol. 2012; 199(5 Suppl):S3-8. DOI: 10.2214/AJR.12.9116. View

5.
Roddy E, Doherty M . Epidemiology of gout. Arthritis Res Ther. 2011; 12(6):223. PMC: 3046529. DOI: 10.1186/ar3199. View