Relationship Between Pre-anesthetic and Intra-anesthetic Airway Resistance in Patients Undergoing General Anesthesia: A Prospective Observational Study
Overview
Affiliations
Surgery patients in Japan undergo routine spirometry testing prior to general anesthesia. The use of a flow sensor during general anesthesia has recently become common. However, it is not certain whether the information derived from flow-volume curves is being adequately used for mechanical ventilation management during general anesthesia. So far, there have been no attempts to calculate airway resistance using flow-volume curves. Therefore, we performed a prospective, observational study to investigate the relationship between pre-anesthetic and intra-anesthetic airway resistance in patients scheduled for surgery under general anesthesia. We calculated pre-anesthetic and intra-anesthetic airway resistance in each patient, based on the slopes of flow-volume curves obtained prior to and during general anesthesia. We also calculated endotracheal tube resistance to correct the intra-anesthetic airway resistance values calculated. A total of 526 patients were included in the study, and 98 patients had a forced expiratory volume in the first second/forced vital capacity ratio of < 70%. Pre-anesthetic airway resistance was significantly higher in patients with airflow obstruction than in those without airflow obstruction (p < 0.001), whereas no significant difference in intra-anesthetic airway resistance was found between patients with and without airflow obstruction during mechanical ventilation (p = 0.48). Pre-anesthetic and intra-anesthetic airway resistance values were closer to each other in patients without airflow obstruction, with a mean difference < 1.0 cmH2O L-1s-1, than in those with airflow obstruction, although these respiratory parameters were significantly different (p < 0.001). Intra-anesthetic airway resistance was not related to the FEV1/FVC ratio, regardless of the degree to which the FEV1/FVC ratio reflected pre-anesthetic airway resistance. As compared with patients with airflow obstruction, the mean difference between pre-anesthetic and intra-anesthetic airway resistance was small in patients without airflow obstruction.
Predictors for intraoperative heart failure in children undergoing foreign-body removal.
Yao X, Zhang L, Zhao G, Pang H, Li T, Han X Medicine (Baltimore). 2021; 100(28):e26626.
PMID: 34260551 PMC: 8284771. DOI: 10.1097/MD.0000000000026626.
Liu H, Wang H, Mu Z, Ye L, Jiang Y Turk Gogus Kalp Damar Cerrahisi Derg. 2021; 28(4):593-600.
PMID: 33403131 PMC: 7759046. DOI: 10.5606/tgkdc.dergisi.2020.20088.
Ikeda T, Yamauchi Y, Uchida K, Oba K, Nagase T, Yamada Y BMC Pulm Med. 2019; 19(1):208.
PMID: 31711456 PMC: 6849182. DOI: 10.1186/s12890-019-0976-6.