Objectives: The objective of this study was to examine the effect of laser lead extraction (LLE) on the development of post-procedural tricuspid regurgitation (TR). Some reports have suggested an increase in TR associated with LLE. We present a series of patients who underwent both, LLE and complete echocardiographic evaluation for TR.
Methods: A single centre analysis of consecutive patients referred for LLE between January 2012 and August 2015. One hundred and three patients had tricuspid valve function evaluated before the procedure with a transthoracic echocardiography (TTE), during the procedure using transoesophageal echocardiography and postoperatively using a TTE. TR was graded from 0 (none) to 4 (severe).
Results: We treated 235 leads in 103 patients, including 118 ventricular leads. Seventy-seven were male (74.8%) and 26 female (25.2%), with a mean age of 65.6 ± 15.4 years. Mean time from initial lead implantation was 98.0 ± 67.3 months. Twenty-one patients (20.4%) had ejection fraction below 30%. No intra-procedural worsening of tricuspid valve function was seen with TEE in any of the patients. Ten patients (9.7%) were found to have TR before LLE that returned to normal valve function after the procedure. Two patients (1.9%) experienced mild TR after the procedure (both with tricuspid valve endocarditis). Ninety-one patients (88.3%) did not experience any significant change of the tricuspid valve function after LLE.
Conclusion: Transthoracic and transoesophageal echocardiography findings showed that laser lead extraction was not associated with a significant increase in the incidence of tricuspid valve regurgitation.
Jachec W, Polewczyk A, Nowosielecka D, Tomaszewski A, Brzozowski W, Szczesniak-Stanczyk D Rev Cardiovasc Med. 2024; 25(6):198.
PMID: 39076327 PMC: 11270083. DOI: 10.31083/j.rcm2506198.
Petersen J, Alassar Y, Yildirim Y, Tonnis T, Reichenspurner H, Pecha S Front Cardiovasc Med. 2023; 10:1129410.
PMID: 36970346 PMC: 10036564. DOI: 10.3389/fcvm.2023.1129410.
Tricuspid Valve Damage Related to Transvenous Lead Extraction.
Polewczyk A, Jachec W, Nowosielecka D, Tomaszewski A, Brzozowski W, Szczesniak-Stanczyk D Int J Environ Res Public Health. 2022; 19(19).
PMID: 36231579 PMC: 9566121. DOI: 10.3390/ijerph191912279.
Tulecki L, Polewczyk A, Jachec W, Nowosielecka D, Tomkow K, Stefanczyk P Int J Environ Res Public Health. 2021; 18(19).
PMID: 34639716 PMC: 8508178. DOI: 10.3390/ijerph181910416.
Tulecki L, Polewczyk A, Jachec W, Nowosielecka D, Tomkow K, Stefanczyk P Int J Environ Res Public Health. 2021; 18(17).
PMID: 34501689 PMC: 8431163. DOI: 10.3390/ijerph18179100.