EEG signals contain a large amount of ocular artifacts with different time-frequency properties mixing together in EEGs of interest. The artifact removal has been substantially dealt with by existing decomposition methods known as PCA and ICA based on the orthogonality of signal vectors or statistical independence of signal components. We focused on the signal morphology and proposed a systematic decomposition method to identify the type of signal components on the basis of sparsity in the time-frequency domain based on Morphological Component Analysis (MCA), which provides a way of reconstruction that guarantees accuracy in reconstruction by using multiple bases in accordance with the concept of "dictionary." MCA was applied to decompose the real EEG signal and clarified the best combination of dictionaries for this purpose. In our proposed semirealistic biological signal analysis with iEEGs recorded from the brain intracranially, those signals were successfully decomposed into original types by a linear expansion of waveforms, such as redundant transforms: UDWT, DCT, LDCT, DST, and DIRAC. Our result demonstrated that the most suitable combination for EEG data analysis was UDWT, DST, and DIRAC to represent the baseline envelope, multifrequency wave-forms, and spiking activities individually as representative types of EEG morphologies.

Citing Articles

Readiness potential reflects the intention of sit-to-stand movement.

Singh B, Natsume K Cogn Neurodyn. 2023; 17(3):605-620.

PMID: 37265646 PMC: 10229514. DOI: 10.1007/s11571-022-09864-5.


Review of electroencephalography signals approaches for mental stress assessment.

Attar E Neurosciences (Riyadh). 2022; 27(4):209-215.

PMID: 36252972 PMC: 9749579. DOI: 10.17712/nsj.2022.4.20220025.


Multimodal signal dataset for 11 intuitive movement tasks from single upper extremity during multiple recording sessions.

Jeong J, Cho J, Shim K, Kwon B, Lee B, Lee D Gigascience. 2020; 9(10).

PMID: 33034634 PMC: 7539536. DOI: 10.1093/gigascience/giaa098.

References
1.
Plochl M, Ossandon J, Konig P . Combining EEG and eye tracking: identification, characterization, and correction of eye movement artifacts in electroencephalographic data. Front Hum Neurosci. 2012; 6:278. PMC: 3466435. DOI: 10.3389/fnhum.2012.00278. View

2.
Donoghue J, Sanes J, Hatsopoulos N, Gaal G . Neural discharge and local field potential oscillations in primate motor cortex during voluntary movements. J Neurophysiol. 1998; 79(1):159-73. DOI: 10.1152/jn.1998.79.1.159. View

3.
Nilsson S, Andersson B . Corneal D.C. recordings of slow ocular potential changes such as the ERG c-wave and the light peak in clinical work. Equipment and examples of results. Doc Ophthalmol. 1988; 68(3-4):313-25. DOI: 10.1007/BF00156437. View

4.
Kotchetkov I, Hwang B, Appelboom G, Kellner C, Connolly Jr E . Brain-computer interfaces: military, neurosurgical, and ethical perspective. Neurosurg Focus. 2010; 28(5):E25. DOI: 10.3171/2010.2.FOCUS1027. View

5.
Starck J, Fadili J, Murtagh F . The undecimated wavelet decomposition and its reconstruction. IEEE Trans Image Process. 2007; 16(2):297-309. DOI: 10.1109/tip.2006.887733. View