» Articles » PMID: 28159535

Wrist-worn Triaxial Accelerometry Predicts the Energy Expenditure of Non-vigorous Daily Physical Activities

Overview
Journal J Sci Med Sport
Specialty Orthopedics
Date 2017 Feb 5
PMID 28159535
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: Triaxial accelerometry is commonly used to estimate oxygen uptake (VO) and energy expenditure in health and fitness studies. We tested the correlation of a triaxial accelerometer in terms of a summation of vector magnitudes with gravity subtracted (SVMgs) and measured VO for different daily physical activities.

Design: Original research, cross-sectional.

Methods: Twenty volunteers wore a triaxial accelerometer on both wrists while performing 12 assigned daily physical activities for 6min for each activity. The VO was determined by indirect calorimetry using a portable metabolic measurement system. The last 3min of each activity was assumed to represent steady-state. The VO measured during these periods was averaged and converted into metabolic equivalents (METs).

Results: The range of VO for all activities was 0.18-3.2L/min (0.8-12.2 METs). Significant differences in SVMgs existed between accelerometer placements on the dominant (120.9±8.7gmin) versus non-dominant hand (99.9±6.8gmin; P=0.016) for the lowest levels of physical activity defined as <1.5 METs. Piecewise linear regression model using 6 METs as the transition point showed similar significant correlations for the non-dominant wrist (r=0.85; P<0.001) and the dominant wrist (r=0.86; P<0.001). Using the non-dominant wrist below 6 METs, the slope of the relationship between SVMgs and METs was 105.3±4.3 (95% CI 96.9 to 113.7) indicating an increase in SVMgs of approximately 100 units for every MET increase in oxygen uptake.

Conclusions: Wrist-worn triaxial accelerometry reliably predicted energy expenditure during common physical activities <6 METs. More consistent correlations were found when the accelerometer was worn on the non-dominant wrist rather than the dominant wrist.

Citing Articles

Combined Impact of Heart Rate Sensor Placements with Respiratory Rate and Minute Ventilation on Oxygen Uptake Prediction.

Lu Z, Yang J, Tao K, Li X, Xu H, Qiu J Sensors (Basel). 2024; 24(16).

PMID: 39205108 PMC: 11360153. DOI: 10.3390/s24165412.


Objectively Measured Physical Activity in Patients with COPD: Recommendations from an International Task Force on Physical Activity.

Demeyer H, Mohan D, Burtin C, Vaes A, Heasley M, Bowler R Chronic Obstr Pulm Dis. 2021; 8(4):528-550.

PMID: 34433239 PMC: 8686852. DOI: 10.15326/jcopdf.2021.0213.


Assessment of Physical Activity in Adults Using Wrist Accelerometers.

Liu F, Wanigatunga A, Schrack J Epidemiol Rev. 2021; 43(1):65-93.

PMID: 34215874 PMC: 8900289. DOI: 10.1093/epirev/mxab004.


Reliability and validity of the physical activity monitor for assessing energy expenditures in sedentary, regularly exercising, non-endurance athlete, and endurance athlete adults.

Chang C, Hsu Y, Li F, Tu Y, Jhang W, Hsu C PeerJ. 2020; 8:e9717.

PMID: 32904158 PMC: 7450994. DOI: 10.7717/peerj.9717.


Feasibility of the Energy Expenditure Prediction for Athletes and Non-Athletes from Ankle-Mounted Accelerometer and Heart Rate Monitor.

Ho C, Chang C, Hsu Y, Tu Y, Li F, Jhang W Sci Rep. 2020; 10(1):8816.

PMID: 32483254 PMC: 7264312. DOI: 10.1038/s41598-020-65713-7.