» Articles » PMID: 28115797

Osteolysis in Total Hip Arthroplasty After Head and Inlay Revision Surgery

Overview
Journal J Orthop
Specialty Orthopedics
Date 2017 Jan 25
PMID 28115797
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Wear debris seems to be the most likely reason for osteolysis in THA. The aim was to show the influence of head and acetabular liner revision surgery on osteolytic zones around the femoral component. Can head and inlay revision surgery reduce the size of the osteolytic zones around the femoral component? Which patients could benefit? 47 patients (51 hips), who had undergone THA head and inlay revision surgery between 1999 and 2011, were reviewed. The mean lifetime for the prosthesis was 15.1 years (8-26, standard deviation 4.5) and the mean follow-up for head and inlay was 39.2 months (12-113, standard deviation 30). The heads used in revision surgery were made of metal (26) and ceramics (25). In 36 cases a ultra-high-molecular-weight polyethylene inlay was taken, in 15 cases a regular PE-inlay. We compared the pre-surgical and follow-up anterior-posterior X-rays. The mean size of radiolucent areas before revision surgery was 147 sq.mm (5-389 sq.mm, standard deviation 115). Thirty-nine months (12-113) after surgery, their mean size was 145 sq.mm (7-604 sq.mm, standard deviation 124). Radiolucent zones exceeding 100 sq.mm could be reduced by an average of 28% in 18 out of 29 cases. The results showed an improvement in 29 out of 51 cases and a stop of progress in one case. According to the findings there may be a benefit for patients with big radiolucent areas.

Citing Articles

Comparative postoperative prognosis of ceramic-on-ceramic and ceramic-on-polyethylene for total hip arthroplasty: an updated systematic review and meta-analysis.

Wu T, Jiang Y, Shi W, Wang Y, Li T PeerJ. 2024; 12:e18139.

PMID: 39346065 PMC: 11438439. DOI: 10.7717/peerj.18139.


Surgical management of hip prosthetic failure in metallosis: A case series and literature review.

Pisanu F, Andreozzi M, Fiori E, Altamore F, Bartoli M, Caggiari G J Orthop. 2021; 28:10-20.

PMID: 34707335 PMC: 8521220. DOI: 10.1016/j.jor.2021.10.002.


Straight stem and threaded cup in patients under 60 years of age: 28.8-30.2 years of follow-up.

Pisecky L, Allerstorfer J, Schauer B, Hipmair G, Hochgatterer R, Bohler N J Orthop Surg Res. 2020; 15(1):563.

PMID: 33243270 PMC: 7691067. DOI: 10.1186/s13018-020-02102-w.


30-Years of experience with the cementless implanted Alloclassic CSF screw cup total hip arthroplasty system - An ultra-long-term follow-up.

Pisecky L, Hipmair G, Schauer B, Bohler N J Orthop. 2019; 16(2):182-186.

PMID: 30899147 PMC: 6406173. DOI: 10.1016/j.jor.2019.02.019.


30-years of experience with the cementless implanted Alloclassic total hip arthroplasty system-An ultra-long-term follow-up.

Pisecky L, Hipmair G, Schauer B, Bohler N J Orthop. 2017; 15(1):18-23.

PMID: 29187778 PMC: 5695608. DOI: 10.1016/j.jor.2017.11.003.

References
1.
Schmalzried T, Jasty M, Harris W . Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg Am. 1992; 74(6):849-63. View

2.
Schmalzried T, Shepherd E, Dorey F, JACKSON W, dela Rosa M, Favae F . The John Charnley Award. Wear is a function of use, not time. Clin Orthop Relat Res. 2000; (381):36-46. DOI: 10.1097/00003086-200012000-00005. View

3.
Gruen T, McNeice G, Amstutz H . "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979; (141):17-27. View

4.
Purdue P, Koulouvaris P, Nestor B, Sculco T . The central role of wear debris in periprosthetic osteolysis. HSS J. 2008; 2(2):102-13. PMC: 2488166. DOI: 10.1007/s11420-006-9003-6. View

5.
Walde T, Weiland D, Leung S, Kitamura N, Sychterz C, Engh Jr C . Comparison of CT, MRI, and radiographs in assessing pelvic osteolysis: a cadaveric study. Clin Orthop Relat Res. 2005; (437):138-44. DOI: 10.1097/01.blo.0000164028.14504.46. View