Objective: To determine, based on indirect calorimetry measurements, the biases of predictive equations specifically developed recently for estimating resting energy expenditure (REE) in ventilated critically ill children, or developed for healthy populations but used in critically ill children.

Study Design: A secondary analysis study was performed using our data on REE measured in a previous prospective study on protein and energy needs in pediatric intensive care unit. We included 75 ventilated critically ill children (median age, 21 months) in whom 407 indirect calorimetry measurements were performed. Fifteen predictive equations were used to estimate REE: the equations of White, Meyer, Mehta, Schofield, Henry, the World Health Organization, Fleisch, and Harris-Benedict and the tables of Talbot. Their differential and proportional biases (with 95% CIs) were computed and the bias plotted in graphs. The Bland-Altman method was also used.

Results: Most equations underestimated and overestimated REE between 200 and 1000 kcal/day. The equations of Mehta, Schofield, and Henry and the tables of Talbot had a bias ≤10%, but the 95% CI was large and contained values by far beyond ±10% for low REE values. Other specific equations for critically ill children had even wider biases.

Conclusions: In ventilated critically ill children, none of the predictive equations tested met the performance criteria for the entire range of REE between 200 and 1000 kcal/day. Even the equations with the smallest bias may entail a risk of underfeeding or overfeeding, especially in the youngest children. Indirect calorimetry measurement must be preferred.

Citing Articles

Components of Total Energy Expenditure in Healthy and Critically Ill Children: A Comprehensive Review.

Parshuram G, Tuira L, Dazo F, El Hariri N, Hulst J, Mtaweh H Nutrients. 2024; 16(16).

PMID: 39203716 PMC: 11357425. DOI: 10.3390/nu16162581.


Accurate height and length estimation in hospitalized children not fulfilling WHO criteria for standard measurement: a multicenter prospective study.

Ford Chessel C, Berthiller J, Haran I, Tume L, Bourgeaud C, Tsapis M Eur J Pediatr. 2024; 183(10):4275-4286.

PMID: 39052138 PMC: 11413069. DOI: 10.1007/s00431-024-05692-3.


The Bland-Altman method should not be used when one of the two measurement methods has negligible measurement errors.

Taffe P, Zuppinger C, Burger G, Nussle S PLoS One. 2022; 17(12):e0278915.

PMID: 36508421 PMC: 9744297. DOI: 10.1371/journal.pone.0278915.


A methodological and clinical approach to measured energy expenditure in the critically ill pediatric patient.

Silva-Gburek J, Zhu P, Mansour M, Walding D, Coss-Bu J Front Pediatr. 2022; 10:1027358.

PMID: 36353257 PMC: 9638495. DOI: 10.3389/fped.2022.1027358.


A Comparative Analysis of Equations to Estimate Patient Energy Requirements Following Cardiopulmonary Bypass for Correction of Congenital Heart Disease.

Roebuck N, Steve Fan C, Floh A, Harris Z, Mazwi M JPEN J Parenter Enteral Nutr. 2019; 44(3):444-453.

PMID: 31209916 PMC: 7078809. DOI: 10.1002/jpen.1610.