Investigation of Time-resolved Proton Radiography Using X-ray Flat-panel Imaging System

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2017 Jan 19
PMID 28099164
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Proton beam therapy benefits from the Bragg peak and delivers highly conformal dose distributions. However, the location of the end-of-range is subject to uncertainties related to the accuracy of the relative proton stopping power estimates and thereby the water-equivalent path length (WEPL) along the beam. To remedy the range uncertainty, an in vivo measurement of the WEPL through the patient, i.e. a proton-range radiograph, is highly desirable. Towards that goal, we have explored a novel method of proton radiography based on the time-resolved dose measured by a flat panel imager (FPI). A 226 MeV pencil beam and a custom-designed range modulator wheel (MW) were used to create a time-varying broad beam. The proton imaging technique used exploits this time dependency by looking at the dose rate at the imager as a function of time. This dose rate function (DRF) has a unique time-varying dose pattern at each depth of penetration. A relatively slow rotation of the MW (0.2 revolutions per second) and a fast image acquisition (30 frames per second, ~33 ms sampling) provided a sufficient temporal resolution for each DRF. Along with the high output of the CsI:Tl scintillator, imaging with pixel binning (2  ×  2) generated high signal-to-noise data at a very low radiation dose (~0.1 cGy). Proton radiographs of a head phantom and a Gammex CT calibration phantom were taken with various configurations. The results of the phantom measurements show that the FPI can generate low noise and high spatial resolution proton radiographs. The WEPL values of the CT tissue surrogate inserts show that the measured relative stopping powers are accurate to ~2%. The panel did not show any noticeable radiation damage after the accumulative dose of approximately 3831 cGy. In summary, we have successfully demonstrated a highly practical method of generating proton radiography using an x-ray flat panel imager.

Citing Articles

A novel proton-integrating radiography system design using a monolithic scintillator detector: experimental studies.

Darne C, Robertson D, Alsanea F, Collins-Fekete C, Beddar S Nucl Instrum Methods Phys Res A. 2022; 1027.

PMID: 35221402 PMC: 8872121. DOI: 10.1016/j.nima.2021.166077.


High quality proton portal imaging using deep learning for proton radiation therapy: a phantom study.

Charyyev S, Lei Y, Harms J, Eaton B, McDonald M, Curran W Biomed Phys Eng Express. 2021; 6(3):035029.

PMID: 33438674 PMC: 11682722. DOI: 10.1088/2057-1976/ab8a74.


A Monte Carlo feasibility study on quantitative laser-driven proton radiography.

Wurl M, Gianoli C, Englbrecht F, Schreiber J, Parodi K Z Med Phys. 2020; 32(1):109-119.

PMID: 32532553 PMC: 9948831. DOI: 10.1016/j.zemedi.2020.05.005.


A novel design of proton computed tomography detected by multiple-layer ionization chamber with strip chambers: A feasibility study with Monte Carlo simulation.

Chen X, Liu R, Zhou S, Sun B, Reynoso F, Mutic S Med Phys. 2019; 47(2):614-625.

PMID: 31705662 PMC: 7996304. DOI: 10.1002/mp.13909.


Time-resolved diode dosimetry calibration through Monte Carlo modeling for in vivo passive scattered proton therapy range verification.

Toltz A, Hoesl M, Schuemann J, Seuntjens J, Lu H, Paganetti H J Appl Clin Med Phys. 2017; 18(6):200-205.

PMID: 29082601 PMC: 5689909. DOI: 10.1002/acm2.12210.