The Evolution of Implant Design Decreases the Incidence of Lateral Release in Primary Total Knee Arthroplasty

Overview
Journal J Arthroplasty
Specialty Orthopedics
Date 2017 Jan 17
PMID 28089467
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Appropriate balancing of the patellofemoral joint (PFJ) using a lateral release can help to prevent patellar instability in total knee arthroplasty (TKA). Contemporary total knee implant designs are characterized by enhanced trochlear geometry more similar to native knee anatomy to minimize instability and reduce utilization of a lateral release.

Methods: We retrospectively reviewed consecutive TKA cases from a single senior surgeon's practice with 3 successive total knee designs: the Press-Fit Condylar (PFC), the Sigma, and the ATTUNE (DePuy, Warsaw, IN). We evaluated the use of lateral release with each implant type to determine if design changes have improved patellar stability, reducing the need for lateral release. We used multivariate analysis to determine the association between implant type and lateral release, adjusting for age, sex, preoperative alignment, and bearing type.

Results: We evaluated 1991 records of primary TKAs performed from 1980-2015. As compared with the ATTUNE, the adjusted odds of lateral release were greater for patients receiving PFC implants (Odds ratio [OR] 6.35, 95% confidence interval [CI] 3.85,10.49) and Sigma implants (OR 2.02, 95% CI 1.26, 3.23). In addition, fixed bearing implants were associated with greater adjusted odds of lateral release (OR 1.80, 95% CI 1.24, 2.62).

Conclusion: We found that older knee implants were associated with higher use of lateral release, with successive designs the need for lateral release to balance the PFJ decreased. Continued design improvements to match the native knee anatomy may further improve the stability of the PFJ in future designs.

Citing Articles

Statistical models and implant customization in hip arthroplasty: Seeking patient satisfaction through design.

Quiceno E, Correa C, Tamayo J, Zuleta A Heliyon. 2024; 10(20):e38832.

PMID: 39506933 PMC: 11538734. DOI: 10.1016/j.heliyon.2024.e38832.


Does lucency equate to revision? A five-year retrospective review of Attune and Triathlon total knee arthroplasty.

ODonovan P, McAleese T, Harty J Knee Surg Sports Traumatol Arthrosc. 2023; 31(11):4773-4781.

PMID: 37516985 PMC: 10598109. DOI: 10.1007/s00167-023-07509-6.


Modern implants in total knee arthroplasty are more patellofemoral joint friendly compared to their traditional design: a systematic review and meta-analysis.

Choudhury A, Gupta K, Ansari S, Raja B, Paul S, Kalia R Arch Orthop Trauma Surg. 2023; 143(9):5873-5889.

PMID: 36961568 DOI: 10.1007/s00402-023-04832-y.


Comparison of Patellofemoral Outcomes between Attune and PFC Sigma Designs: A Prospective Matched-Pair Analysis.

Maniar R, Bhatnagar N, Bidwai R, Dhiman A, Chanda D, Sanghavi N Clin Orthop Surg. 2022; 14(1):96-104.

PMID: 35251546 PMC: 8858905. DOI: 10.4055/cios20130.


Loading on Attune® fixed-bearing cruciate-substituting total knee implant in knee malalignment during activities of daily living: A finite element analysis.

Shetty G, Khairkar S J Orthop. 2021; 26:36-41.

PMID: 34290486 PMC: 8280525. DOI: 10.1016/j.jor.2021.07.002.