Intraocular lens (IOL) is an efficient implantable device commonly used for treating cataracts. However, bioadhesion of bacteria or residual lens epithelial cells on the IOL surface after surgery causes postoperative complications, such as endophthalmitis or posterior capsular opacification, and leads to loss of sight again. In the present study, zwitterionic polymer brushes were fabricated on the IOL surface via bottom-up grafting procedure. The attenuated total reflection-Fourier transform infrared and contact angle measurements indicated successful surface modification, as well as excellent hydrophilicity. The coating of hydrophilic zwitterionic polymer effectively decreased the bioadhesion of lens epithelial cells or bacteria. In vivo intraocular implantation results showed good in vivo biocompatibility of zwitterionic IOL and its effectiveness against postoperative complications.

Citing Articles

How do intraocular lens materials influence the outcome of cataract surgery?.

Grzybowski A, Auffarth G, LaHood B Curr Opin Ophthalmol. 2024; 36(1):18-24.

PMID: 39446645 PMC: 11620326. DOI: 10.1097/ICU.0000000000001095.


Application of Silicone in Ophthalmology: A Review.

Mladenovic T, Zivic F, Petrovic N, Njezic S, Pavic J, Kotorcevic N Materials (Basel). 2024; 17(14).

PMID: 39063747 PMC: 11278226. DOI: 10.3390/ma17143454.


Rapid and Economical Drug-Eluting IOL Preparation via Thermoresponsive Agarose Coating for Effective Posterior Capsular Opacification Prevention.

Chen S, Qin C, Fang Q, Duo L, Wang M, Deng Z Front Bioeng Biotechnol. 2022; 10:930540.

PMID: 35992334 PMC: 9388942. DOI: 10.3389/fbioe.2022.930540.


Research Progress Concerning a Novel Intraocular Lens for the Prevention of Posterior Capsular Opacification.

Zhang Y, Zhang C, Chen S, Hu J, Shen L, Yu Y Pharmaceutics. 2022; 14(7).

PMID: 35890240 PMC: 9318653. DOI: 10.3390/pharmaceutics14071343.


Recent Advances of Intraocular Lens Materials and Surface Modification in Cataract Surgery.

Luo C, Wang H, Chen X, Xu J, Yin H, Yao K Front Bioeng Biotechnol. 2022; 10:913383.

PMID: 35757812 PMC: 9213654. DOI: 10.3389/fbioe.2022.913383.


References
1.
Lin Q, Ren K, Ji J . Hyaluronic acid and chitosan-DNA complex multilayered thin film as surface-mediated nonviral gene delivery system. Colloids Surf B Biointerfaces. 2009; 74(1):298-303. DOI: 10.1016/j.colsurfb.2009.07.036. View

2.
DSa R, Burke G, Meenan B . Lens epithelial cell response to atmospheric pressure plasma modified poly(methylmethacrylate) surfaces. J Mater Sci Mater Med. 2010; 21(5):1703-12. DOI: 10.1007/s10856-010-4030-8. View

3.
Huang C, Chu S, Wang L, Li C, Lee T . Bioinspired Zwitterionic Surface Coatings with Robust Photostability and Fouling Resistance. ACS Appl Mater Interfaces. 2015; 7(42):23776-86. DOI: 10.1021/acsami.5b08418. View

4.
Li D, Cui F, Gu H . F+ ion implantation induced cell attachment on intraocular lens. Biomaterials. 1999; 20(20):1889-96. DOI: 10.1016/s0142-9612(99)00084-8. View

5.
Lin Q, Yan J, Qiu F, Song X, Fu G, Ji J . Heparin/collagen multilayer as a thromboresistant and endothelial favorable coating for intravascular stent. J Biomed Mater Res A. 2010; 96(1):132-41. DOI: 10.1002/jbm.a.32820. View