» Articles » PMID: 2801531

Noninvasive Assessment of Central Circulatory Pressures by Analysis of Ear Densitographic Changes During the Valsalva Maneuver

Overview
Journal Am J Cardiol
Date 1989 Oct 1
PMID 2801531
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

The ear densitogram was monitored in 21 consecutive patients with various degrees of myocardial function (New York Heart Association class I to IV) during the standardized Valsalva maneuver to evaluate the quantitative relations between the pattern of response and the central circulatory pressures. The ear densitographic first derivative consistently tracked the aortic pulse pressure during the strain phase of the Valsalva maneuver (beat-to-beat correlation [r] range 0.98 to 0.72). The percent decrease of the densitographic pulse derivative during strain correlated with left ventricular end-diastolic pressure at rest (r = 0.62, p less than 0.001), but not with cardiac output, cardiac index and ejection fraction. Multiple stepwise regression was used to take into account multiple aspects (time intervals and pulse amplitudes) of the pattern of response to the Valsalva maneuver. As a result, both correlations improved substantially (r = 0.97, p less than 0.001 for left ventricular end-diastolic pressure, and r = 0.92, p less than 0.001 for pulmonary artery wedge pressure). In conclusion, the combination of several noninvasive indexes obtained by pulse amplitude and interval changes during the strain phase of the Valsalva maneuver seems to be a new and promising method for noninvasive evaluation of the status of left ventricular filling pressures.

Citing Articles

A finger photoplethysmography waveform during the valsalva maneuver detects changes in left heart filling pressure after hemodialysis.

Galiatsatos P, Parakh K, Monti J, Thavarajah S, Aneke-Ogbu H, Watson A BMC Nephrol. 2015; 16:138.

PMID: 26272208 PMC: 4536782. DOI: 10.1186/s12882-015-0135-0.


Finger photoplethysmography during the Valsalva maneuver reflects left ventricular filling pressure.

Silber H, Trost J, Johnston P, Maughan W, Wang N, Kasper E Am J Physiol Heart Circ Physiol. 2012; 302(10):H2043-7.

PMID: 22389389 PMC: 3774124. DOI: 10.1152/ajpheart.00609.2011.


Pulse transit time by R-wave-gated infrared photoplethysmography: review of the literature and personal experience.

Naschitz J, Bezobchuk S, Mussafia-Priselac R, Sundick S, Dreyfuss D, Khorshidi I J Clin Monit Comput. 2005; 18(5-6):333-42.

PMID: 15957624 DOI: 10.1007/s10877-005-4300-z.