» Articles » PMID: 28009845

Improvement of Depth Profiling into Biotissues Using Micro Electrical Impedance Spectroscopy on a Needle with Selective Passivation

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2016 Dec 24
PMID 28009845
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

A micro electrical impedance spectroscopy (EIS)-on-a-needle for depth profiling (μEoN-DP) with a selective passivation layer (SPL) on a hypodermic needle was recently fabricated to measure the electrical impedance of biotissues along with the penetration depths. The SPL of the μEoN-DP enabled the sensing interdigitated electrodes (IDEs) to contribute predominantly to the measurement by reducing the relative influence of the connection lines on the sensor output. The discrimination capability of the μEoN-DP was verified using phosphate-buffered saline (PBS) at various concentration levels. The resistance and capacitance extracted through curve fitting were similar to those theoretically estimated based on the mixing ratio of PBS and deionized water; the maximum discrepancies were 8.02% and 1.85%, respectively. Depth profiling was conducted using four-layered porcine tissue to verify the effectiveness of the discrimination capability of the μEoN-DP. The magnitude and phase between dissimilar porcine tissues (fat and muscle) were clearly discriminated at the optimal frequency of 1 MHz. Two kinds of simulations, one with SPL and the other with complete passivation layer (CPL), were performed, and it was verified that the SPL was advantageous over CPL in the discrimination of biotissues in terms of sensor output.

Citing Articles

Sensor-Embedded Automatic Grasping Forceps for Precise Corneal Suture in Penetrating Keratoplasty.

Shin H, Park I, Kim K, Kim H, Chung W Micromachines (Basel). 2021; 12(5).

PMID: 33922770 PMC: 8145369. DOI: 10.3390/mi12050484.


Real-Time Impedance Detection of Intra-Articular Space in a Porcine Model Using a Monopolar Injection Needle.

Abbasi M, Kim H, Chinnadayyala S, Park K, Cho S Sensors (Basel). 2020; 20(16).

PMID: 32824575 PMC: 7472031. DOI: 10.3390/s20164625.


Lock-in Amplifier-Based Impedance Detection of Tissue Type Using a Monopolar Injection Needle.

Kim J, Abbasi M, Kim T, Park K, Cho S Sensors (Basel). 2019; 19(21).

PMID: 31652819 PMC: 6864682. DOI: 10.3390/s19214614.


Gauging electrical properties of bone with a bioimpedance-sensing drill.

Butler R, Halter R Physiol Meas. 2018; 40(1):01NT01.

PMID: 30530942 PMC: 6752961. DOI: 10.1088/1361-6579/aaf75a.


Fabrication of Fine Electrodes on the Tip of Hypodermic Needle Using Photoresist Spray Coating and Flexible Photomask for Biomedical Applications.

Yun J, Kim J, Lee J J Vis Exp. 2017; (129).

PMID: 29286396 PMC: 5755490. DOI: 10.3791/56622.

References
1.
Schwan H . Linear and nonlinear electrode polarization and biological materials. Ann Biomed Eng. 1992; 20(3):269-88. DOI: 10.1007/BF02368531. View

2.
Wahjudi P, Oh J, Salman S, Seabold J, Rodger D, Tai Y . Improvement of metal and tissue adhesion on surface-modified parylene C. J Biomed Mater Res A. 2008; 89(1):206-14. DOI: 10.1002/jbm.a.31929. View

3.
Zang F, Gerasopoulos K, Fan X, Brown A, Culver J, Ghodssi R . Real-time monitoring of macromolecular biosensing probe self-assembly and on-chip ELISA using impedimetric microsensors. Biosens Bioelectron. 2016; 81:401-407. DOI: 10.1016/j.bios.2016.03.019. View

4.
Keshtkar A, Salehnia Z, Somi M, Eftekharsadat A . Some early results related to electrical impedance of normal and abnormal gastric tissue. Phys Med. 2011; 28(1):19-24. DOI: 10.1016/j.ejmp.2011.01.002. View

5.
Kang G, Kim Y, Moon H, Lee J, Yoo T, Park K . Discrimination between the human prostate normal cell and cancer cell by using a novel electrical impedance spectroscopy controlling the cross-sectional area of a microfluidic channel. Biomicrofluidics. 2014; 7(4):44126. PMC: 3772938. DOI: 10.1063/1.4818838. View