» Articles » PMID: 27989581

Influence of Temperature on Cyclic Fatigue Resistance of ProTaper Gold and ProTaper Universal Rotary Files

Overview
Journal J Endod
Publisher Elsevier
Specialty Dentistry
Date 2016 Dec 20
PMID 27989581
Citations 51
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: The aim of this study was to evaluate the cyclic fatigue resistance of ProTaper Universal (PTU; Dentsply Maillefer, Baillagues, Switzerland) and ProTaper Gold (PTG, Dentsply Maillefer) nickel-titanium rotary files at room and intracanal temperatures.

Methods: A total of 120 files were used to test the cyclic fatigue resistance of PTU (S1 and F2) and PTG (S1 and F2) in an artificial canal at room temperature (20°C) and at intracanal temperature (35°C). The number of cycles to failure and the fracture length of the fragment were recorded, and data were subjected to statistical analysis.

Results: PTG registered no differences in fatigue life between the 2 temperatures tested (P > .05), whereas PTU showed a statistically significant reduction in fatigue life at intracanal temperature compared with room temperature (P < .05). PTG instruments exhibited a statistically higher resistance to cyclic fatigue than PTU instruments both at room and intracanal temperatures (P < .05). There were no statistically significant differences among the fracture length of separated instruments (P > .05).

Conclusions: Intracanal temperature influenced the cyclic fatigue resistance of instruments produced with traditional nickel-titanium, whereas it did not influence the fatigue life of instruments produced with gold heat treatment. Gold heating treatment enhances the resistance to cyclic fatigue of ProTaper instruments.

Citing Articles

Comparative Analysis of NiTi Instruments with Different Alloy Treatments.

Aranguren J, Oliveros-Porras F, Ramirez-Munoz A, Perez I, Salamanca-Ramos M, Aazzouzi-Raiss K Materials (Basel). 2024; 17(19).

PMID: 39410388 PMC: 11477650. DOI: 10.3390/ma17194817.


Effect of several nickel-titanium rotary systems on stress distribution in mandibular molars under occlusal forces: a finite element analysis.

Sonmez S, Koc C Odontology. 2024; .

PMID: 39242406 DOI: 10.1007/s10266-024-01002-3.


Evaluation of Cyclic Fatigue Resistance of Novel Replica-Like Instruments in Static Test Model.

Aydin U, Ozdemir M, Culha E, Basturk Ozer M, Turan B Appl Bionics Biomech. 2024; 2024:8842478.

PMID: 39206445 PMC: 11357823. DOI: 10.1155/2024/8842478.


Comprehensive Assessment of Cyclic Fatigue Strength in Five Multiple-File Nickel-Titanium Endodontic Systems.

Martins J, Silva E, Marques D, Braz Fernandes F, Versiani M Materials (Basel). 2024; 17(10).

PMID: 38793413 PMC: 11123240. DOI: 10.3390/ma17102345.


Assessment of the Cyclic Fatigue Performance of the Novel Protaper Ultimate File System Used in Different Kinematics: An In Vitro Study.

Diaconu C, Diaconu A, Tuculina M, Mihai L, Gheorghita M, Gheorghita L J Funct Biomater. 2024; 15(4).

PMID: 38667542 PMC: 11051539. DOI: 10.3390/jfb15040085.