Magnetic fields from neuronal action potentials (APs) pass largely unperturbed through biological tissue, allowing magnetic measurements of AP dynamics to be performed extracellularly or even outside intact organisms. To date, however, magnetic techniques for sensing neuronal activity have either operated at the macroscale with coarse spatial and/or temporal resolution-e.g., magnetic resonance imaging methods and magnetoencephalography-or been restricted to biophysics studies of excised neurons probed with cryogenic or bulky detectors that do not provide single-neuron spatial resolution and are not scalable to functional networks or intact organisms. Here, we show that AP magnetic sensing can be realized with both single-neuron sensitivity and intact organism applicability using optically probed nitrogen-vacancy (NV) quantum defects in diamond, operated under ambient conditions and with the NV diamond sensor in close proximity (∼10 µm) to the biological sample. We demonstrate this method for excised single neurons from marine worm and squid, and then exterior to intact, optically opaque marine worms for extended periods and with no observed adverse effect on the animal. NV diamond magnetometry is noninvasive and label-free and does not cause photodamage. The method provides precise measurement of AP waveforms from individual neurons, as well as magnetic field correlates of the AP conduction velocity, and directly determines the AP propagation direction through the inherent sensitivity of NVs to the associated AP magnetic field vector.

Citing Articles

Nanophotonic quantum sensing with engineered spin-optic coupling.

Kim L, Choi H, Trusheim M, Wang H, Englund D Nanophotonics. 2024; 12(3):441-449.

PMID: 39635412 PMC: 11502022. DOI: 10.1515/nanoph-2022-0682.


A spin-refrigerated cavity quantum electrodynamic sensor.

Wang H, Tiwari K, Jacobs K, Judy M, Zhang X, Englund D Nat Commun. 2024; 15(1):10320.

PMID: 39609376 PMC: 11605127. DOI: 10.1038/s41467-024-54333-8.


Functionalized Nanodiamonds for Targeted Neuronal Electromagnetic Signal Detection.

Costa B, Camarneiro F, Marote A, Barbosa C, Vedor C, Tome D ACS Appl Mater Interfaces. 2024; 16(44):60828-60841.

PMID: 39445729 PMC: 11551900. DOI: 10.1021/acsami.4c12462.


Imaging magnetic transition of magnetite to megabar pressures using quantum sensors in diamond anvil cell.

Wang M, Wang Y, Liu Z, Xu G, Yang B, Yu P Nat Commun. 2024; 15(1):8843.

PMID: 39397023 PMC: 11471789. DOI: 10.1038/s41467-024-52272-y.


Probing Bioinorganic Electron Spin Decoherence Mechanisms with an FeS Metalloprotein.

Totoiu C, Follmer A, Oyala P, Hadt R J Phys Chem B. 2024; 128(42):10417-10426.

PMID: 39392916 PMC: 11514009. DOI: 10.1021/acs.jpcb.4c06186.


References
1.
Shapiro M, Priest M, Siegel P, Bezanilla F . Thermal mechanisms of millimeter wave stimulation of excitable cells. Biophys J. 2013; 104(12):2622-8. PMC: 3686354. DOI: 10.1016/j.bpj.2013.05.014. View

2.
Kucsko G, Maurer P, Yao N, Kubo M, Noh H, Lo P . Nanometre-scale thermometry in a living cell. Nature. 2013; 500(7460):54-8. PMC: 4221854. DOI: 10.1038/nature12373. View

3.
Tan S, Roth B, Wikswo Jr J . The magnetic field of cortical current sources: the application of a spatial filtering model to the forward and inverse problems. Electroencephalogr Clin Neurophysiol. 1990; 76(1):73-85. DOI: 10.1016/0013-4694(90)90059-s. View

4.
Fang K, Acosta V, Santori C, Huang Z, Itoh K, Watanabe H . High-sensitivity magnetometry based on quantum beats in diamond nitrogen-vacancy centers. Phys Rev Lett. 2013; 110(13):130802. DOI: 10.1103/PhysRevLett.110.130802. View

5.
Sundaram P, Nummenmaa A, Wells W, Orbach D, Orringer D, Mulkern R . Direct neural current imaging in an intact cerebellum with magnetic resonance imaging. Neuroimage. 2016; 132:477-490. PMC: 4873157. DOI: 10.1016/j.neuroimage.2016.01.059. View