Assessing Arsenic and Selenium in a Single Nail Clipping Using Portable X-ray Fluorescence

Overview
Date 2016 Nov 28
PMID 27889549
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

The feasibility of measuring arsenic and selenium contents in a single nail clipping was investigated using a small-focus portable X-ray fluorescence (XRF) instrument with monochromatic excitation beams. Nail clipping phantoms supplemented with arsenic and selenium to produce materials with 0, 5, 10, 15, and 20µg/g were used for calibration purposes. In total, 10 different clippings were analyzed at two different measurement positions. Energy spectra were fit with detection peaks for arsenic K, selenium K, arsenic K, selenium K, and bromine K characteristic X-rays. Data analysis was performed under two distinct conditions of fitting constraint. Calibration lines were established from the amplitude of each of the arsenic and selenium peaks as a function of the elemental contents in the clippings. The slopes of the four calibration lines were consistent between the two conditions of analysis. The calculated minimum detection limit (MDL) of the method, when considering the K peak only, ranged from 0.210±0.002µg/g selenium under one condition of analysis to 0.777±0.009µg/g selenium under another. Compared with previous portable XRF nail clipping studies, MDLs were substantially improved for both arsenic and selenium. The new measurement technique had the additional benefits of being short in duration (~3min) and requiring only a single nail clipping. The mass of the individual clipping used did not appear to play a major role in signal strength, but positioning of the clipping is important.

Citing Articles

Ways to Measure Metals: From ICP-MS to XRF.

Adesina K, Burgos C, Grier T, Sayam A, Specht A Curr Environ Health Rep. 2025; 12(1):7.

PMID: 39865194 DOI: 10.1007/s40572-025-00473-y.


Detection of Arsenic(V) by Fluorescence Sensing Based on Chlorin e6-Copper Ion.

Luo M, Chen G, Wang J, Chai T, Qian Z, Li W Molecules. 2024; 29(5).

PMID: 38474527 PMC: 10934122. DOI: 10.3390/molecules29051015.


Portable X-ray Fluorescence as a Rapid Determination Tool to Detect Parts per Million Levels of Ni, Zn, As, Se, and Pb in Human Toenails: A South India Case Study.

Bhatia M, Specht A, Ramya V, Sulaiman D, Konda M, Balcom P Environ Sci Technol. 2021; 55(19):13113-13121.

PMID: 34529917 PMC: 8582015. DOI: 10.1021/acs.est.1c00937.


Validation of in vivo toenail measurements of manganese and mercury using a portable X-ray fluorescence device.

Specht A, Zhang X, Young A, Nguyen V, Christiani D, Ceballos D J Expo Sci Environ Epidemiol. 2021; 32(3):427-433.

PMID: 34211112 PMC: 8720103. DOI: 10.1038/s41370-021-00358-w.


A novel calibration for L-shell x-ray fluorescence measurements of bone lead concentration using the strontium K/Kratio.

Gherase M, Serna B, Kroeker S Physiol Meas. 2021; 42(4).

PMID: 33857933 PMC: 8177726. DOI: 10.1088/1361-6579/abf886.