» Articles » PMID: 27862058

Translation of First North American 50 and 70 Cc Total Artificial Heart Virtual and Clinical Implantations: Utility of 3D Computed Tomography to Test Fit Devices

Overview
Journal Artif Organs
Date 2016 Nov 19
PMID 27862058
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Since the creation of SynCardia's 50 cc Total Artificial Hearts (TAHs), patients with irreversible biventricular failure now have two sizing options. Herein, a case series of three patients who have undergone successful 50 and 70 cc TAH implantation with complete closure of the chest cavity utilizing preoperative "virtual implantation" of different sized devices for surgical planning are presented. Computed tomography (CT) images were used for preoperative planning prior to TAH implantation. Three-dimensional (3D) reconstructions of preoperative chest CT images were generated and both 50 and 70 cc TAHs were virtually implanted into patients' thoracic cavities. During the simulation, the TAHs were projected over the native hearts in a similar position to the actual implantation, and the relationship between the devices and the atria, ventricles, chest wall, and diaphragm were assessed. The 3D reconstructed images and virtual modeling were used to simulate and determine for each patient if the 50 or 70 cc TAH would have a higher likelihood of successful implantation without complications. Subsequently, all three patients received clinical implants of the properly sized TAH based on virtual modeling, and their chest cavities were fully closed. This virtual implantation increases our confidence that the selected TAH will better fit within the thoracic cavity allowing for improved surgical outcome. Clinical implantation of the TAHs showed that our virtual modeling was an effective method for determining the correct fit and sizing of 50 and 70 cc TAHs.

Citing Articles

Preoperative Computed Tomography Virtual Simulation for HeartMate 3 Implantation in Small Children.

Furuta A, Shinkawa T, Ichihara Y, Yoshida H, Niinami H Ann Thorac Surg Short Rep. 2025; 2(3):404-406.

PMID: 39790379 PMC: 11708546. DOI: 10.1016/j.atssr.2024.04.015.


Human fitting of pediatric and infant continuous-flow total artificial heart: visual and virtual assessment.

Miyagi C, Ahmad M, Karimov J, Polakowski A, Karamlou T, Yaman M Front Cardiovasc Med. 2023; 10:1193800.

PMID: 37529709 PMC: 10387526. DOI: 10.3389/fcvm.2023.1193800.


Virtual reality: a useful simulation tool for planning and training.

Sharma D, Subramaniam K Indian J Thorac Cardiovasc Surg. 2021; 38(1):113-114.

PMID: 34898891 PMC: 8630301. DOI: 10.1007/s12055-021-01243-9.


Using virtual reality simulated implantation for fit-testing pediatric patients for adult ventricular assist devices.

Davies R, Hussain T, Tandon A JTCVS Tech. 2021; 6:134-137.

PMID: 34318173 PMC: 8300477. DOI: 10.1016/j.xjtc.2020.10.017.


Insertion of the total artificial heart in the Fontan circulation.

Jaquiss R, Woods R Ann Cardiothorac Surg. 2020; 9(2):134-140.

PMID: 32309168 PMC: 7160629. DOI: 10.21037/acs.2020.03.11.