» Articles » PMID: 27852673

Progress in Quantitative Viral Load Testing: Variability and Impact of the WHO Quantitative International Standards

Overview
Specialty Microbiology
Date 2016 Nov 18
PMID 27852673
Citations 31
Authors
Affiliations
Soon will be listed here.
Abstract

It has been hoped that the recent availability of WHO quantitative standards would improve interlaboratory agreement for viral load testing; however, insufficient data are available to evaluate whether this has been the case. Results from 554 laboratories participating in proficiency testing surveys for quantitative PCR assays of cytomegalovirus (CMV), Epstein-Barr virus (EBV), BK virus (BKV), adenovirus (ADV), and human herpesvirus 6 (HHV6) were evaluated to determine overall result variability and then were stratified by assay manufacturer. The impact of calibration to international units/ml (CMV and EBV) on variability was also determined. Viral loads showed a high degree of interlaboratory variability for all tested viruses, with interquartile ranges as high as 1.46 log copies/ml and the overall range for a given sample up to 5.66 log copies/ml. Some improvement in result variability was seen when international units were adopted. This was particularly the case for EBV viral load results. Variability in viral load results remains a challenge across all viruses tested here; introduction of international quantitative standards may help reduce variability and does so more or less markedly for certain viruses.

Citing Articles

The impact of FDA-cleared molecular solutions for BK polyomavirus quantitation.

Parikh B, Anderson N J Clin Microbiol. 2025; 63(3):e0034824.

PMID: 39818950 PMC: 11898770. DOI: 10.1128/jcm.00348-24.


Evaluation of the performance of a qPCR-based assay for HIV-1 viral load determination.

Lin B, Han C, Li J, Wang R PLoS One. 2024; 19(12):e0315579.

PMID: 39671356 PMC: 11642942. DOI: 10.1371/journal.pone.0315579.


Laboratory validation of a clinical metagenomic next-generation sequencing assay for respiratory virus detection and discovery.

Tan J, Servellita V, Stryke D, Kelly E, Streithorst J, Sumimoto N Nat Commun. 2024; 15(1):9016.

PMID: 39532844 PMC: 11558004. DOI: 10.1038/s41467-024-51470-y.


Antiviral Agents for Preventing Cytomegalovirus Disease in Recipients of Hematopoietic Cell Transplantation.

Jaing T, Wang Y, Chiu C Viruses. 2024; 16(8).

PMID: 39205242 PMC: 11359103. DOI: 10.3390/v16081268.


Performance of the cobas EBV and cobas BKV assays: multi-site comparison of standardized quantitation.

Mannonen L, Jokela P, Thomsen M, Yerly S, Cilla G, Jarem D J Clin Microbiol. 2024; 62(8):e0026724.

PMID: 39046255 PMC: 11323559. DOI: 10.1128/jcm.00267-24.


References
1.
Holden M, Madej R, Minor P, Kalman L . Molecular diagnostics: harmonization through reference materials, documentary standards and proficiency testing. Expert Rev Mol Diagn. 2011; 11(7):741-55. DOI: 10.1586/erm.11.50. View

2.
Gantzer M, Miller W . Harmonisation of Measurement Procedures: how do we get it done?. Clin Biochem Rev. 2012; 33(3):95-100. PMC: 3428258. View

3.
Hoffman N, Cook L, Atienza E, Limaye A, Jerome K . Marked variability of BK virus load measurement using quantitative real-time PCR among commonly used assays. J Clin Microbiol. 2008; 46(8):2671-80. PMC: 2519469. DOI: 10.1128/JCM.00258-08. View

4.
Madej R, Davis J, Holden M, Kwang S, Labourier E, Schneider G . International standards and reference materials for quantitative molecular infectious disease testing. J Mol Diagn. 2010; 12(2):133-43. PMC: 2871718. DOI: 10.2353/jmoldx.2010.090067. View

5.
Abeynayake J, Johnson R, Libiran P, Sahoo M, Cao H, Bowen R . Commutability of the Epstein-Barr virus WHO international standard across two quantitative PCR methods. J Clin Microbiol. 2014; 52(10):3802-4. PMC: 4187779. DOI: 10.1128/JCM.01676-14. View