Quantum Yields for Laser Photocyclization of Bilirubin in the Presence of Human Serum Albumin. Dependence of Quantum Yield on Excitation Wavelength

Overview
Date 1989 Sep 1
PMID 2780821
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

The quantum yield for laser photocyclization of bilirubin to lumirubin in the presence of human serum albumin (phi LR) was measured at five monochromatic excitation wavelengths in the range 450-530 nm. Solutions used were optically thin throughout the wavelength range and precautions were taken to exclude contributions from photocyclization of bilirubin XIII alpha impurities. The values obtained (7.2-18 x 10(-4] were lower than those previously reported and showed the following wavelength dependence: 457.9 less than 488.0 less than 501.7 less than 514.5 approximately equal to 528.7. However, the rate of lumirubin formation, normalized to constant fluence, decreased with wavelength over the same wavelength range and no evidence was found that photoisomerization of bilirubin to lumirubin is faster with green (514.5 or 528.7 nm) than with blue (457.9 or 488.0 nm) light. The stereoselectivity of the configurational isomerization of bilirubin to 4Z,15E and 4E,15Z isomers also was studied. This reaction became less regioselective for the 4Z,15E isomer with increasing wavelength. The observed wavelength dependence of phi LR and of the [4E,15Z]: [4Z,15E] ratio at photoequilibrium are consistent with an exciton coupling model in which intramolecular energy transfer can occur between the two pyrromethenone chromophores of the bilirubin molecule in the excited state. Relative rates of lumirubin formation in vivo at different excitation wavelengths and constant fluence were estimated for different optical thicknesses and for different skin thicknesses. These estimates suggest that the recently reported clinical equivalence of blue and green phototherapy lights probably reflects the marked variation of skin transmittance with wavelength more than wavelength-dependent photochemistry. The calculations also indicated that the optimal wavelength for phototherapy is probably on the long wavelength side of the bilirubin absorption maximum.

Citing Articles

Bilirubin isomers during LED phototherapy of hyperbilirubinemic neonates, blue-green (~478 nm) vs blue.

Ebbesen F, Madsen P, Rodrigo-Domingo M, Donneborg M Pediatr Res. 2024; .

PMID: 39232092 DOI: 10.1038/s41390-024-03493-w.


SpeCamX: mobile app that turns unmodified smartphones into multispectral imagers.

He Q, Li W, Shi Y, Yu Y, Geng W, Sun Z Biomed Opt Express. 2023; 14(9):4929-4946.

PMID: 37791269 PMC: 10545193. DOI: 10.1364/BOE.497602.


Blue-Green (~480 nm) versus Blue (~460 nm) Light for Newborn Phototherapy-Safety Considerations.

Ebbesen F, Vreman H, Hansen T Int J Mol Sci. 2023; 24(1).

PMID: 36613904 PMC: 9820095. DOI: 10.3390/ijms24010461.


Microfluidic photoreactor to treat neonatal jaundice.

Lahmann J, Faase R, Leu H, Jacques S, Scottoline B, Schilke K Biomicrofluidics. 2021; 15(6):064104.

PMID: 34853627 PMC: 8616629. DOI: 10.1063/5.0066073.


Action spectrum of phototherapy in hyperbilirubinemic neonates.

Ebbesen F, Donneborg M, Vandborg P, Vreman H Pediatr Res. 2021; 92(3):816-821.

PMID: 34789840 DOI: 10.1038/s41390-021-01743-9.