» Articles » PMID: 27741121

Optic Nerve Sheath Diameter Threshold by Ocular Ultrasonography for Detection of Increased Intracranial Pressure in Korean Adult Patients with Brain Lesions

Overview
Specialty General Medicine
Date 2016 Oct 15
PMID 27741121
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

Optic nerve sheath diameter (ONSD) seen on ocular US has been associated with increased intracranial pressure (IICP). However, most studies have analyzed normal range of ONSD and its optimal cut-off point for IICP in Caucasian populations. Considering ONSD differences according to ethnicity, previous results may not accurately reflect the association between IICP and ONSD in Koreans. Therefore, we conducted this study to investigate normal range of ONSD and its optimal threshold for detecting IICP in Korean patients.This prospective multicenter study was performed for patients with suspected IICP. ONSD was measured 3 mm behind the globe using a 13-MHz US probe. IICP was defined as significant brain edema, midline shift, compression of ventricle or basal cistern, effacement of sulci, insufficient gray/white differentiation, and transfalcine herniation by radiologic tests. The results of the ONSD are described as the median (25th-75th percentile). The differences of ONSD according to disease entity were analyzed. A receiver operator characteristic (ROC) curve was generated to determine the optimal cut-off point for identifying IICP.A total of 134 patients were enrolled. The patients were divided into 3 groups as follows: patients with IICP, n = 81 (60.5%); patients without IICP, n = 27 (20.1%); and control group, n = 26 (19.4%). ONSD in patients with IICP (5.9 mm [5.8-6.2]) is significantly higher than those without IICP (5.2 mm [4.8-5.4]) (P < 0.01) and normal control group (4.9 mm [4.6-5.2]) (P < 0.001). Between patients without IICP and normal control group, the difference of ONSD did not reach statistical significance (P = 0.31). ONSD >5.5 mm yielded a sensitivity of 98.77% (95% CI: 93.3%-100%) and a specificity of 85.19% (95% CI: 66.3%-95.8%).In conclusion, the optimal cut-off point of ONSD for identifying IICP was 5.5 mm. ONSD seen on ocular US can be a feasible method for detection and serial monitoring of ICP in Korean adult patients.

Citing Articles

Evaluation of optic nerve sheath diameter in patients undergoing laparoscopic surgery in the Trendelenburg position: a prospective observational study.

Omur B, Ciftci B, Karaaslan P Ann Saudi Med. 2024; 44(5):319-328.

PMID: 39368121 PMC: 11454954. DOI: 10.5144/0256-4947.2024.319.


Diagnostic dilemma of papilledema and pseudopapilledema.

El-Gendy R, El-Hamid A, Galhom A, Hassan N, Ghoneim E Int Ophthalmol. 2024; 44(1):272.

PMID: 38916684 DOI: 10.1007/s10792-024-03215-5.


Optic nerve sheath diameter measurement for prediction of postdural puncture headache.

Boyaci S, Onay M, Gulec M J Clin Monit Comput. 2023; 38(2):415-422.

PMID: 37555877 DOI: 10.1007/s10877-023-01067-5.


Extracorporeal Circulation and Optic Nerve Ultrasound: A Pilot Study.

Taskin O, Demir U Medicina (Kaunas). 2023; 59(3).

PMID: 36984445 PMC: 10058668. DOI: 10.3390/medicina59030445.


Ultrasound measurement of optic nerve sheath diameter in a healthy adult Colombian population.

Trocha G, Bonilla A, Romero C, Palacios J, Molano-Gonzalez N BMC Neurol. 2023; 23(1):16.

PMID: 36639617 PMC: 9837461. DOI: 10.1186/s12883-023-03062-4.


References
1.
Friedman D, Liu G, Digre K . Revised diagnostic criteria for the pseudotumor cerebri syndrome in adults and children. Neurology. 2013; 81(13):1159-65. DOI: 10.1212/WNL.0b013e3182a55f17. View

2.
Warden K, Alizai A, Trobe J, Hoff J . Short-term continuous intraparenchymal intracranial pressure monitoring in presumed idiopathic intracranial hypertension. J Neuroophthalmol. 2011; 31(3):202-5. DOI: 10.1097/WNO.0b013e3182183c8d. View

3.
Cartwright C, Igbaseimokumo U . Lumbar puncture opening pressure is not a reliable measure of intracranial pressure in children. J Child Neurol. 2014; 30(2):170-3. DOI: 10.1177/0883073814533006. View

4.
Todd Miller M, Pasquale M, Kurek S, White J, Martin P, Bannon K . Initial head computed tomographic scan characteristics have a linear relationship with initial intracranial pressure after trauma. J Trauma. 2004; 56(5):967-72. DOI: 10.1097/01.ta.0000123699.16465.8b. View

5.
Girisgin A, Kalkan E, Kocak S, Cander B, Gul M, Semiz M . The role of optic nerve ultrasonography in the diagnosis of elevated intracranial pressure. Emerg Med J. 2007; 24(4):251-4. PMC: 2658229. DOI: 10.1136/emj.2006.040931. View