The Importance of State and Context in Safe Interoperable Medical Systems

Overview
Date 2016 Oct 13
PMID 27730013
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

This paper describes why "device state" and "patient context" information are necessary components of device models for safe interoperability. This paper includes a discussion of the importance of describing the roles of devices with respect to interactions (including human user workflows involving devices, and device to device communication) within a system, particularly those intended for use at the point-of-care, and how this role information is communicated. In addition, it describes the importance of clinical scenarios in creating device models for interoperable devices.

Citing Articles

An Open-Source, Interoperable Architecture for Generating Real-Time Surgical Team Cognitive Alerts from Heart-Rate Variability Monitoring.

Arney D, Zhang Y, Kennedy-Metz L, Dias R, Goldman J, Zenati M Sensors (Basel). 2023; 23(8).

PMID: 37112231 PMC: 10145698. DOI: 10.3390/s23083890.


Unified Open Hardware Platform for Digital X-Ray Devices; its Conceptual Model and First Implementation.

Durmaz F, Brusan A, Ozturk C IEEE J Transl Eng Health Med. 2020; 8:1800311.

PMID: 32617198 PMC: 7326152. DOI: 10.1109/JTEHM.2020.3000011.


Establishing a Ventilator-Heart Lung Machine Communication Bridge to Mitigate Errors when Weaning from Bypass.

Rance G, Arney D, Srey R, Goldman J, Zenati M J Extra Corpor Technol. 2019; 51(1):38-40.

PMID: 30936587 PMC: 6436169.


Collaborative Paradigm of Preventive, Personalized, and Precision Medicine With Point-of-Care Technologies.

Dhawan A IEEE J Transl Eng Health Med. 2017; 4:2800908.

PMID: 28560119 PMC: 5396943. DOI: 10.1109/JTEHM.2016.2635126.

References
1.
Kawagishi T, Kanaya N, Nakayama M, Kurosawa S, Namiki A . A comparison of the failure times of pulse oximeters during blood pressure cuff-induced hypoperfusion in volunteers. Anesth Analg. 2004; 99(3):793-796. DOI: 10.1213/01.ANE.0000130343.66453.37. View

2.
Langevin P, Hellein V, Harms S, Tharp W, Lampotang S . Synchronization of radiograph film exposure with the inspiratory pause. Effect on the appearance of bedside chest radiographs in mechanically ventilated patients. Am J Respir Crit Care Med. 1999; 160(6):2067-71. DOI: 10.1164/ajrccm.160.6.9902060. View

3.
Ranganath V, Kim Y, Hatcliff J, Robby . Communication patterns for interconnecting and composing medical systems. Annu Int Conf IEEE Eng Med Biol Soc. 2016; 2015:1711-6. DOI: 10.1109/EMBC.2015.7318707. View

4.
Arney D, Bhatia K, Bhatia S, Sutton M, Rausch T, Karlinsky J . Design of an x-ray / ventilator synchronization system in an integrated clinical environment. Annu Int Conf IEEE Eng Med Biol Soc. 2012; 2011:8203-6. DOI: 10.1109/IEMBS.2011.6092023. View

5.
Goldman J . Solving the interoperability challenge: safe and reliable information exchange requires more from product designers. IEEE Pulse. 2014; 5(6):37-9. DOI: 10.1109/MPUL.2014.2355307. View