» Articles » PMID: 27709893

Development and Calibration of an Organic-Diffusive Gradients in Thin Films Aquatic Passive Sampler for a Diverse Suite of Polar Organic Contaminants

Overview
Journal Anal Chem
Specialty Chemistry
Date 2016 Oct 7
PMID 27709893
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

A unique configuration of the diffusive gradients in thin films sampler for polar organics (o-DGT) without a poly(ether sulfone) membrane was developed, calibrated, and field-evaluated. Diffusion coefficients (D) through agarose diffusive gels ranged from (1.02 to 4.74) × 10 cm/s for 34 pharmaceuticals and pesticides at 5, 13, and 23 °C. Analyte-specific diffusion-temperature plots produced linear (r > 0.85) empirical relationships whereby D could be estimated at any environmentally relevant temperature (i.e., matched to in situ water conditions). Linear uptake for all analytes was observed in a static renewal calibration experiment over 25 days except for three macrolide antibiotics, which reached saturation at 300 ng (≈15 d). Experimental sampling rates ranged from 8.8 to 16.1 mL/d and were successfully estimated with measured and modeled D within 19% and 30% average relative error, respectively. Under slow flowing (2.4 cm/s) and static conditions, the in situ diffusive boundary layer (DBL) thickness ranged from 0.023 to 0.075 cm, resulting in a maximum contribution to mass transfer of <45%. Estimated water concentrations by o-DGT at a wastewater treatment plant agreed well with grab samples and appeared to be less influenced by the boundary layer compared to that of polar organic chemical integrative samplers (POCIS) deployed simultaneously. The o-DGT sampler is a promising monitoring tool that is largely insensitive to the DBL under typical flow conditions, facilitating the application of measured/modeled diffusion-based sampling rates. This significantly reduces the need for sampler calibration, making o-DGT more widely applicable, reliable, and cost-effective compared to current polar passive samplers.

Citing Articles

Development of High Surface Area Organosilicate Nanoparticulate Thin Films for Use in Sensing Hydrophobic Compounds in Sediment and Water.

Bok S, Korampally V, Stanley J, Gangopadhyay K, Gangopadhyay S, Steevens J Biosensors (Basel). 2024; 14(6).

PMID: 38920592 PMC: 11201756. DOI: 10.3390/bios14060288.


Non-Steady-State Fickian Diffusion Models Decrease the Estimated Gel Layer Diffusion Coefficient Uncertainty for Diffusive Gradients in Thin-Films Passive Samplers.

Hodges S, Wahman D, Haupert L, Pham H, Bozarth M, Howland M Environ Sci Technol. 2023; 57(26):9793-9801.

PMID: 37342010 PMC: 10324599. DOI: 10.1021/acs.est.3c01861.


Development and applications of diffusive gradients in thin films for monitoring pharmaceuticals in surface waters.

Cao H, Bu Q, Li Q, Gao X, Xie H, Gong W Environ Pollut. 2022; 311:119979.

PMID: 35988678 PMC: 9386599. DOI: 10.1016/j.envpol.2022.119979.


Field Validation of a Novel Passive Sampler for Dissolved PFAS in Surface Waters.

Gardiner C, Robuck A, Becanova J, Cantwell M, Kaserzon S, Katz D Environ Toxicol Chem. 2022; 41(10):2375-2385.

PMID: 35833595 PMC: 9558079. DOI: 10.1002/etc.5431.


Assessment of pesticides in water using time-weighted average calibration of passive sampling device manufactured with carbon nanomaterial coating on stainless steel wire.

Valenzuela E, de Paula F, Teixeira A, Menezes H, Cardeal Z Anal Bioanal Chem. 2021; 413(12):3315-3327.

PMID: 33733701 DOI: 10.1007/s00216-021-03270-2.