Quality Control in Screening for Infectious Diseases at Blood Banks. Rationale and Methodology

Overview
Journal EJIFCC
Specialty Biochemistry
Date 2016 Sep 30
PMID 27683500
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Quality control procedures are indispensable to ensure the reliability of the results provided by laboratories responsible for serological screening in blood banks. International recommendations on systems of quality management classify as a top component the inclusion of two types of control: (a) internal quality control (IQC) and (b) external quality control (EQC). In EQC it is essential to have, at least, a monthly frequency of laboratory assessment. On the other hand, IQC involves the daily use of low-reactivity control sera, which should be systematically added in all run, carried out in the laboratory for each parameter. Through the IQC analysis some variations in the criteria of run acceptance and rejection may be revealed, but it is of paramount importance to ensure the previous definition of these criteria and even more importantly, the adherence to them; and that corresponds to the validation of analytical runs of each test. Since 2010 this has been, for instance, the experience of the PNCQ*, developing external quality control programmes on serology for blood banks. These programmes use samples of lyophilized sera well-characterized for the reactivity related to the parameters used for the serological screening of blood donors. The programmes have used blind panels of six samples for monthly assessments. In the last 50 assessments, which involved 68 blood banks in Brazil, a significant number of instances of non-compliance were observed in all monthly assessments. These results provide strong support to the recommendation of systematic monthly assessments. (*) National Quality Control Programme (PNCQ).

Citing Articles

Applying sigma metrics to assess quality control processes in the transfusion transmissible infection screening laboratory of a blood center.

Bhatnagar S, Westgard S, Dung N, Que T, Khanh B, Thanh N PLoS One. 2024; 19(10):e0312422.

PMID: 39446744 PMC: 11500874. DOI: 10.1371/journal.pone.0312422.


External quality control program in infectious diseases screening at laboratories and blood banks in Latin America: an analysis of the past 5 years.

Mendrone-Junior A, Salles N, Otani M, Countinho A, Alves L, Rocha V Rev Panam Salud Publica. 2023; 47:e162.

PMID: 38089105 PMC: 10712573. DOI: 10.26633/RPSP.2023.162.


Assessment of the Key Performance Indicator Proposed by NABH in the Blood Centre of a Tertiary Health Care Hospital in Southern India.

Gnanaraj J, Kulkarni R, Sahoo D, Abhishekh B Indian J Hematol Blood Transfus. 2023; 39(2):308-316.

PMID: 37006976 PMC: 10064356. DOI: 10.1007/s12288-022-01563-9.


Implementation of internal quality control program for monitoring of enzyme-linked immunosorbent assay performance at a blood center.

Dubey A, Sonker A Asian J Transfus Sci. 2021; 15(1):21-29.

PMID: 34349453 PMC: 8294434. DOI: 10.4103/ajts.AJTS_59_19.

References
1.
Grijalva M, Chiriboga R, Vanhassel H, Arcos-Teran L . Improving the safety of the blood supply in Ecuador through external performance evaluation of serological screening of blood donors. J Clin Virol. 2006; 34 Suppl 2:S47-52. DOI: 10.1016/s1386-6532(05)80034-4. View

2.
Saez-Alquezar A, Murta M, Pereira Marques W, Silva G . [The results of an external quality control program for serological screening for antibodies against Trypanosoma cruzi in blood donors in Brazil]. Rev Panam Salud Publica. 2003; 13(2-3):129-37. DOI: 10.1590/s1020-49892003000200014. View

3.
Otani M, Sabino E, Salles N, Chamone D . Evaluation of the performance of Brazilian blood banks in testing for Chagas' disease. Vox Sang. 1998; 74(4):228-31. View

4.
Oknaian S, Remesar M, Ferraro L, del Pozo A . [External performance evaluation of screening in blood banks in Argentina: results and strategies for improvement]. Rev Panam Salud Publica. 2003; 13(2-3):149-53. DOI: 10.1590/s1020-49892003000200017. View

5.
Saez-Alquezar A, Otani M, Sabino E, Salles N, Chamone D . [External serology quality control programs developed in Latin America with the support of PAHO from 1997 through 2000]. Rev Panam Salud Publica. 2003; 13(2-3):91-102. DOI: 10.1590/s1020-49892003000200009. View