Standardization in Clinical Enzymology

Overview
Journal EJIFCC
Specialty Biochemistry
Date 2016 Sep 30
PMID 27683339
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

The goal of standardization in Laboratory Medicine is to achieve comparable results in human samples, independent of the reagent kits, instruments, and laboratory where the assay is carried out. To pursue this objective in clinical enzymology, the IFCC has established reference measurement systems for the most important clinical enzymes. These systems are based on the following requirements: a) reference methods, well described in procedures that are extensively evaluated; b) suitable reference materials; and c) reference laboratories operating in a highly controlled manner. Using these reference systems and the manufacturer's standing procedures, industry can assign traceable values to commercial calibrators. Clinical laboratories, which use routine procedures with validated calibrators to measure enzymes in human specimens, can finally obtain values which are traceable to higher-order reference procedures. These reference systems constitute the structure of the traceability chain to which the enzyme routine methods can be linked via an appropriate calibration process, provided that they have a comparable specificity (i.e. they are measuring the same quantity).

Citing Articles

The role of EQA in harmonization in laboratory medicine - a global effort.

Jones G Biochem Med (Zagreb). 2017; 27(1):23-29.

PMID: 28392723 PMC: 5382853. DOI: 10.11613/BM.2017.004.


Bias Assessment of General Chemistry Analytes using Commutable Samples.

Koerbin G, Tate J, Ryan J, Jones G, Sikaris K, Kanowski D Clin Biochem Rev. 2015; 35(4):203-11.

PMID: 25678726 PMC: 4310060.

References
1.
Panteghini M, Ceriotti F, Schumann G, Siekmann L . Establishing a reference system in clinical enzymology. Clin Chem Lab Med. 2001; 39(9):795-800. DOI: 10.1515/CCLM.2001.131. View

2.
Rej R . Accurate enzyme activity measurements. Two decades of development in the commutability of enzyme quality control materials. Arch Pathol Lab Med. 1993; 117(4):352-64. View

3.
Siekmann L, Bonora R, Burtis C, Ceriotti F, Clerc-Renaud P, Ferard G . IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 7. Certification of four reference materials for the.... Clin Chem Lab Med. 2002; 40(7):739-45. DOI: 10.1515/CCLM.2002.127. View

4.
Schumann G, Bonora R, Ceriotti F, Clerc-Renaud P, Ferrero C, Ferard G . IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. Part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase. Clin Chem Lab Med. 2002; 40(6):635-42. DOI: 10.1515/CCLM.2002.110. View

5.
Schumann G, Bonora R, Ceriotti F, Clerc-Renaud P, Ferrero C, Ferard G . IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase. Clin Chem Lab Med. 2002; 40(6):643-8. DOI: 10.1515/CCLM.2002.111. View