In Vivo Precision of Three HR-pQCT-derived Finite Element Models of the Distal Radius and Tibia in Postmenopausal Women

Overview
Publisher Biomed Central
Specialties Orthopedics
Physiology
Date 2016 Sep 14
PMID 27619649
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The distal radius is the most common osteoporotic fracture site occurring in postmenopausal women. Finite element (FE) modeling is a non-invasive mathematical technique that can estimate bone strength using inputted geometry/micro-architecture and tissue material properties from computed tomographic images. Our first objective was to define and compare in vivo precision errors for three high-resolution peripheral quantitative computed tomography (HR-pQCT, XtremeCT; Scanco) based FE models of the distal radius and tibia in postmenopausal women. Our second objective was to assess the role of scan interval, scan quality, and common region on precision errors of outcomes for each FE model.

Methods: Models included: single-tissue model (STM), cortical-trabecular dual-tissue model (DTM), and one scaled model using imaged bone mineral density (E-BMD). Using HR-pQCT, we scanned the distal radius and tibia of 34 postmenopausal women (74 ± 7 years), at two time points. Primary outcomes included: tissue stiffness, apparent modulus, average von Mises stress, and failure load. Precision errors (root-mean-squared coefficient of variation, CV%RMS) were calculated. Multivariate ANOVA was used to compare the mean of individual CV% among the 3 HR-pQCT-based FE models. Spearman correlations were used to characterize the associations between precision errors of all FE model outcomes and scan/time interval, scan quality, and common region. Significance was accepted at P < 0.05.

Results: At the distal radius, CV%RMS precision errors were <9 % (Range STM: 2.8-5.3 %; DTM: 2.9-5.4 %; E-BMD: 4.4-8.7 %). At the distal tibia, CV%RMS precision errors were <6 % (Range STM: 2.7-4.8 %; DTM: 2.9-3.8 %; E-BMD: 1.8-2.5 %). At the radius, Spearman correlations indicated associations between the common region and associated precision errors of the E-BMD-derived apparent modulus (ρ = -0.392; P < 0.001) and von Mises stress (ρ = -0.297; P = 0.007).

Conclusion: Results suggest that the STM and DTM are more precise for modeling apparent modulus, average von Mises stress, and failure load at the distal radius. Precision errors were comparable for all three models at the distal tibia. Results indicate that the noted differences in precision error at the distal radius were associated with the common scan region, illustrating the importance of participant repositioning within the cast and reference line placement in the scout view during the scanning process.

Citing Articles

Biomechanics of a Drop Landing: Osteogenic Stimulus Measures May Vary.

Wilzman A, Wong D, Troy K J Musculoskelet Neuronal Interact. 2025; 25(1):1-17.

PMID: 40024223 PMC: 11880855. DOI: 10.22540/JMNI-25-001.


Quantifying Bone Strength Deficits in Young Adults Born Extremely Preterm or Extremely Low Birth Weight.

Dao T, Robinson D, Doyle L, Lee P, Olsen J, Kale A J Bone Miner Res. 2023; 38(12):1800-1808.

PMID: 37850817 PMC: 10946901. DOI: 10.1002/jbmr.4926.


Documenting the Anisotropic Stiffness of Hard Tissues with Resonant Ultrasound Spectroscopy.

Cai X, Bernard S, Grimal Q Adv Exp Med Biol. 2022; 1364:279-295.

PMID: 35508880 DOI: 10.1007/978-3-030-91979-5_13.


Peripheral quantitative computed tomography (pQCT)-based finite element analysis provides enhanced diagnostic performance in identifying non-vertebral fracture patients compared with dual-energy X-ray absorptiometry.

Jiang H, Robinson D, Yates C, Lee P, Wark J Osteoporos Int. 2019; 31(1):141-151.

PMID: 31720708 DOI: 10.1007/s00198-019-05213-1.


Mechanical Metrics of the Proximal Tibia are Precise and Differentiate Osteoarthritic and Normal Knees: A Finite Element Study.

Arjmand H, Nazemi M, Kontulainen S, McLennan C, Hunter D, Wilson D Sci Rep. 2018; 8(1):11478.

PMID: 30065276 PMC: 6068127. DOI: 10.1038/s41598-018-29880-y.

References
1.
Gluer C . Monitoring skeletal changes by radiological techniques. J Bone Miner Res. 1999; 14(11):1952-62. DOI: 10.1359/jbmr.1999.14.11.1952. View

2.
van Rietbergen B, Weinans H, Huiskes R, Odgaard A . A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models. J Biomech. 1995; 28(1):69-81. DOI: 10.1016/0021-9290(95)80008-5. View

3.
Varga P, Pahr D, Baumbach S, Zysset P . HR-pQCT based FE analysis of the most distal radius section provides an improved prediction of Colles' fracture load in vitro. Bone. 2010; 47(5):982-8. DOI: 10.1016/j.bone.2010.08.002. View

4.
Papaioannou A, Morin S, Cheung A, Atkinson S, Brown J, Feldman S . 2010 clinical practice guidelines for the diagnosis and management of osteoporosis in Canada: summary. CMAJ. 2010; 182(17):1864-73. PMC: 2988535. DOI: 10.1503/cmaj.100771. View

5.
Vilayphiou N, Boutroy S, Szulc P, van Rietbergen B, Munoz F, Delmas P . Finite element analysis performed on radius and tibia HR-pQCT images and fragility fractures at all sites in men. J Bone Miner Res. 2011; 26(5):965-73. DOI: 10.1002/jbmr.297. View