» Articles » PMID: 27617093

Holter Monitoring and Loop Recorders: From Research to Clinical Practice

Overview
Date 2016 Sep 13
PMID 27617093
Citations 27
Authors
Affiliations
Soon will be listed here.
Abstract

Holter monitors are tools of proven efficacy in diagnosing and monitoring cardiac arrhythmias. Despite the fact their use is widely prescribed by general practitioners, little is known about their evolving role in the management of patients with cryptogenic stroke, paroxysmal atrial fibrillation, unexplained recurrent syncope and risk stratification in implantable cardioverter defibrillator or pacemaker candidates. New Holter monitoring technologies and loop recorders allow prolonged monitoring of heart rhythm for periods from a few days to several months, making it possible to detect infrequent arrhythmias in patients of all ages. This review discusses the advances in this area of arrhythmology and how Holter monitors have improved the clinical management of patients with suspected cardiac rhythm diseases.

Citing Articles

Cough monitoring systems in adults with chronic respiratory diseases: a systematic review.

Witjaksono L, Schulte M, Holland A, Wijsenbeek M, Khor Y Eur Respir Rev. 2025; 34(175).

PMID: 40044185 PMC: 11880901. DOI: 10.1183/16000617.0212-2023.


Wearables and Atrial Fibrillation: Advances in Detection, Clinical Impact, Ethical Concerns, and Future Perspectives.

Francisco A, Pascoal C, Lamborne P, Morais H, Goncalves M Cureus. 2025; 17(1):e77404.

PMID: 39949464 PMC: 11822239. DOI: 10.7759/cureus.77404.


Comprehensive Analysis of Cardiovascular Diseases: Symptoms, Diagnosis, and AI Innovations.

Khan M, Haider Z, Hussain J, Malik F, Talib I, Abdullah S Bioengineering (Basel). 2025; 11(12.

PMID: 39768057 PMC: 11673700. DOI: 10.3390/bioengineering11121239.


Cost-Minimization Model in Cryptogenic Stroke: ePatch vs Implantable Loop Recorder in Patients from the UK, Netherlands, and Sweden.

Lukyanov V, Parikh P, Wadhwa M, Dunn A, van Leerdam R, Engdahl J Med Devices (Auckl). 2024; 17:471-490.

PMID: 39655268 PMC: 11626978. DOI: 10.2147/MDER.S492389.


Harnessing the Heart's Magnetic Field for Advanced Diagnostic Techniques.

Elfouly T, Alouani A Sensors (Basel). 2024; 24(18).

PMID: 39338762 PMC: 11435997. DOI: 10.3390/s24186017.


References
1.
Gimeno-Blanes F, Blanco-Velasco M, Barquero-Perez O, Garcia-Alberola A, Rojo-Alvarez J . Sudden Cardiac Risk Stratification with Electrocardiographic Indices - A Review on Computational Processing, Technology Transfer, and Scientific Evidence. Front Physiol. 2016; 7:82. PMC: 4780431. DOI: 10.3389/fphys.2016.00082. View

2.
Healey J, Connolly S . Atrial fibrillation: hypertension as a causative agent, risk factor for complications, and potential therapeutic target. Am J Cardiol. 2003; 91(10A):9G-14G. DOI: 10.1016/s0002-9149(03)00227-3. View

3.
Pachulski R, Cockrell J, Solomon H, Yang F, Rogers J . Implant evaluation of an insertable cardiac monitor outside the electrophysiology lab setting. PLoS One. 2013; 8(8):e71544. PMC: 3744555. DOI: 10.1371/journal.pone.0071544. View

4.
Bass E, Curtiss E, Arena V, Hanusa B, Cecchetti A, Karpf M . The duration of Holter monitoring in patients with syncope. Is 24 hours enough?. Arch Intern Med. 1990; 150(5):1073-8. View

5.
Sayed R, Rogers D, Khan F, Wechalekar A, Lachmann H, Fontana M . A study of implanted cardiac rhythm recorders in advanced cardiac AL amyloidosis. Eur Heart J. 2015; 36(18):1098-105. DOI: 10.1093/eurheartj/ehu506. View