» Articles » PMID: 27612607

A Comparison of Radiographic Outcomes After Total Hip Arthroplasty Between the Posterior Approach and Direct Anterior Approach With Intraoperative Fluoroscopy

Overview
Journal J Arthroplasty
Specialty Orthopedics
Date 2016 Sep 11
PMID 27612607
Citations 28
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Radiographic outcomes after total hip arthroplasty (THA) have been linked to clinical outcomes. The direct anterior approach (DAA) for THA has been criticized by some for providing limited exposure and compromised implant position but allows for routine use of intraoperative fluoroscopy. We sought to determine whether radiographic measurements differed by THA approach using prospective cohorts.

Methods: Two reviewers blinded to surgical approach examined 194 radiographs, obtained 4-6 weeks after primary THA, and obtained measurements for acetabular inclination angle, acetabular anteversion, radiographic limb length discrepancy (LLD), and femoral offset. All surgeries were performed at a tertiary academic medical center in rural New England by an experienced fellowship-trained arthroplasty surgeon. Measurements for inclination angle, anteversion, LLD, and offset were made into binary yes/no responses based on whether the mean measurement (between the 2 reviewers) was acceptable or not based on established criteria. Multivariate logistic regression analyses were performed using preoperative and intraoperative characteristics to identify predictors of acceptability for each measurement.

Results: The DAA group had higher rates of acceptable acetabular angle (96 vs 85%, P = .005) and was protective against an unacceptable angle in an adjusted predictive model (odds ratios 0.16, P = .005). There were no significant differences between approaches for acceptable anteversion, LLD, or offset. Body mass index of 30-34 was associated with higher odds of unacceptable inclination angle compared to the nonobese group (adjusted odds ratio, 6.82, P = .013).

Conclusion: DAA for THA was associated with lower odds of unacceptable inclination angle compared to the posterior approach, with no differences in anteversion, LLD, or offset.

Citing Articles

Efficacy of a novel, fluoroscopy-based robotic-assisted total hip arthroplasty system in restoring limb length and offset.

Buchan G, Hecht 2nd C, Nugent M, Heckmann N, Kanaji A, Kamath A Arch Orthop Trauma Surg. 2025; 145(1):175.

PMID: 40042653 DOI: 10.1007/s00402-024-05648-0.


Optimizing implant positioning in total hip arthroplasty via the direct anterior approach: The role and technique of conventional traction table and fluoroscopy.

Ishii S, Baba T, Hayashi K, Homma Y, Muto O, Ishijima M Arthroplasty. 2025; 7(1):10.

PMID: 39915885 PMC: 11804042. DOI: 10.1186/s42836-024-00293-9.


Spinopelvic Motion Evaluation in Patients Undergoing Total Hip Arthroplasty and Patient-Specific Target for Acetabular Cup Placement.

Koutalos A, Gkekas N, Akrivos V, Stefanou N, Karachalios T J Pers Med. 2024; 14(12).

PMID: 39728073 PMC: 11678274. DOI: 10.3390/jpm14121161.


Does the utilization of fluoroscopy affect the accuracy of prosthesis position in patients undergoing hip replacement surgery via the direct anterior approach compared to the posterolateral approach for an experienced surgeon? A single-center....

Wu P, Chang W, Chen K, Huang P, Ho C, Chien C BMC Musculoskelet Disord. 2024; 25(1):816.

PMID: 39407225 PMC: 11476075. DOI: 10.1186/s12891-024-07917-w.


Leg length discrepancy after total hip arthroplasty performed by direct anterior approach: a systematic review comparing surgical approaches and strategies for prevention.

Tassinari L, Di Martino A, Brunello M, Rossomando V, Traina F, Faldini C EFORT Open Rev. 2024; 9(8):733-744.

PMID: 39087513 PMC: 11370713. DOI: 10.1530/EOR-23-0116.


References
1.
Lewinnek G, Lewis J, Tarr R, COMPERE C, Zimmerman J . Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978; 60(2):217-20. View

2.
Bal B, Haltom D, Aleto T, Barrett M . Early complications of primary total hip replacement performed with a two-incision minimally invasive technique. Surgical technique. J Bone Joint Surg Am. 2006; 88 Suppl 1 Pt 2:221-33. DOI: 10.2106/JBJS.F.00326. View

3.
Jewett B, Collis D . High complication rate with anterior total hip arthroplasties on a fracture table. Clin Orthop Relat Res. 2010; 469(2):503-7. PMC: 3018203. DOI: 10.1007/s11999-010-1568-1. View

4.
Goytia R, Jones L, Hungerford M . Learning curve for the anterior approach total hip arthroplasty. J Surg Orthop Adv. 2012; 21(2):78-83. DOI: 10.3113/jsoa.2012.0078. View

5.
Matta J, Shahrdar C, Ferguson T . Single-incision anterior approach for total hip arthroplasty on an orthopaedic table. Clin Orthop Relat Res. 2005; 441:115-24. DOI: 10.1097/01.blo.0000194309.70518.cb. View