» Articles » PMID: 27609447

A Novel Approach Using Electromagnetic Neuronavigation and a Flexible Neuroendoscope for Placement of Ommaya Reservoirs

Overview
Journal World Neurosurg
Publisher Elsevier
Date 2016 Sep 10
PMID 27609447
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Placement of intraventricular catheters in oncology patients can be associated with morbidity given their small to slit-like ventricles and underlying hematologic disorders. We studied the accuracy of placing Ommaya reservoirs using neuronavigation and a flexible neuroendoscope to verify catheter positioning.

Methods: Ommaya reservoirs placed in 25 oncology patients between 2013 and 2015 were retrospectively reviewed. Twenty-five ventricular catheters were placed using the AxiEM stealth frameless neuronavigation system and a flexible neuroendoscope. Postoperative catheter accuracy, operative complications, and postoperative complications were assessed. We discuss surgical protocol and technical nuances.

Results: All ventricular catheters were successfully placed into the ipsilateral (84%) or contralateral (16%) foramen of Monro. A single ventricular catheter pass was needed to cannulate the ventricle in 96% of patients. The mean accuracy was 4.09 ± 3.47 mm from the target, the ipsilateral foramen of Monro. One patient had a catheter tract hemorrhage seen on postoperative imaging related to thrombocytopenia. No postoperative neurologic deficits were seen.

Conclusions: A combined neuronavigation and neuroendoscopic approach improved catheter tip accuracy compared with accuracy rates described in the literature using other techniques. This approach can be adapted toward routine clinical practice of placing ventricular shunt catheters and Ommaya reservoirs.

Citing Articles

A review on intrathecal administration of medications for leptomeningeal metastases in solid tumors.

Wang X, Yao C, Quan L, Zhou J Front Pharmacol. 2025; 16:1472945.

PMID: 39981182 PMC: 11841460. DOI: 10.3389/fphar.2025.1472945.


Advances in the treatment of Adamantinomatous craniopharyngioma: How to balance tumor control and quality of life in the current environment: a narrative review.

Chen A, Ai M, Sun T Front Oncol. 2024; 13:1326595.

PMID: 38188294 PMC: 10771305. DOI: 10.3389/fonc.2023.1326595.


Ommaya reservoir placement using ultrasound guidance via anterior fontanelle combined with frameless electromagnetic neuronavigation in patients with mucopolysaccharidosis type 2: Case reports and review of the literature.

Mizushima M, Kawabori M, Yamazaki K, Egawa K, Fujimura M Childs Nerv Syst. 2024; 40(5):1603-1607.

PMID: 38165414 DOI: 10.1007/s00381-023-06265-9.


THE SAFETY AND EFFICACY OF ROBOT-ASSISTED STEREOTACTIC BIOPSY FOR BRAIN GLIOMA: EARLIEST INSTITUTIONAL EXPERIENCES AND EVALUATION OF LITERATURE.

Rotim K, Splavski B, Vrban F Acta Clin Croat. 2021; 60(2):296-303.

PMID: 34744281 PMC: 8564848. DOI: 10.20471/acc.2021.60.02.17.


[Use of Ommaya Reservoirs to Deliver Pemetrexed in Leptomeningeal Metastasis from Non-small Cell Lung Cancer: A Case Report and Review of the Literature].

Lin Y, Li H, Huang M, Guo A, Yin Z Zhongguo Fei Ai Za Zhi. 2019; 22(8):546-550.

PMID: 31451148 PMC: 6717864. DOI: 10.3779/j.issn.1009-3419.2019.08.12.