Measurement of Lean Body Mass Using Bioelectrical Impedance Analysis: a Consideration of the Pros and Cons

Overview
Publisher Springer
Specialty Geriatrics
Date 2016 Aug 29
PMID 27568020
Citations 113
Authors
Affiliations
Soon will be listed here.
Abstract

The assessment of body composition has important applications in the evaluation of nutritional status and estimating potential health risks. Bioelectrical impedance analysis (BIA) is a valid method for the assessment of body composition. BIA is an alternative to more invasive and expensive methods like dual-energy X-ray absorptiometry, computerized tomography, and magnetic resonance imaging. Bioelectrical impedance analysis is an easy-to-use and low-cost method for the estimation of fat-free mass (FFM) in physiological and pathological conditions. The reliability of BIA measurements is influenced by various factors related to the instrument itself, including electrodes, operator, subject, and environment. BIA assumptions beyond its use for body composition are the human body is empirically composed of cylinders, FFM contains virtually all the water and conducting electrolytes in the body, and its hydration is constant. FFM can be predicted by BIA through equations developed using reference methods. Several BIA prediction equations exist for the estimation of FFM, skeletal muscle mass (SMM), or appendicular SMM. The BIA prediction models differ according to the characteristics of the sample in which they have been derived and validated in addition to the parameters included in the multiple regression analysis. In choosing BIA equations, it is important to consider the characteristics of the sample in which it has been developed and validated, since, for example, age- and ethnicity-related differences could sensitively affect BIA estimates.

Citing Articles

BIA-derived muscle indicator thresholds for malnutrition risk prediction in children with β-thalassemia: a cross-sectional study.

Zhang L, Long J, Wang L, Zhang L, Yang Y, Patil S Eur J Med Res. 2025; 30(1):142.

PMID: 40016835 PMC: 11866567. DOI: 10.1186/s40001-025-02392-y.


Effect of gold nanoparticles treatment on rats-induced obesity by evaluating body-composition directly and indirectly via bioelectric impedance analysis.

Selima R, Saleem I, Shawki M, Darwish A, Yehia M, Mohamed E Sci Rep. 2025; 15(1):4942.

PMID: 39929902 PMC: 11811030. DOI: 10.1038/s41598-025-87971-z.


Variable power functional dilution adjustment of spot urine.

Carmine T Sci Rep. 2025; 15(1):3688.

PMID: 39885184 PMC: 11782553. DOI: 10.1038/s41598-024-84442-9.


Eight Weeks of Resistance Training Is Not a Sufficient Stimulus to Improve Body Composition in Post-COVID-19 Elderly Adults.

Kaczmarczyk K, Ploszczyca K, Jaskulski K, Czuba M J Clin Med. 2025; 14(1.

PMID: 39797257 PMC: 11721171. DOI: 10.3390/jcm14010174.


Use of phase angle as an indicator of overtraining in sport and physical training.

Annunziata G, Paoli A, Frias-Toral E, Marra S, Campa F, Verde L J Transl Med. 2024; 22(1):1084.

PMID: 39614271 PMC: 11605935. DOI: 10.1186/s12967-024-05918-w.