Abstract

The auditory evoked N1m-P2m response complex presents a challenging case for MEG source-modelling, because symmetrical, phase-locked activity occurs in the hemispheres both contralateral and ipsilateral to stimulation. Beamformer methods, in particular, can be susceptible to localisation bias and spurious sources under these conditions. This study explored the accuracy and efficiency of event-related beamformer source models for auditory MEG data under typical experimental conditions: monaural and diotic stimulation; and whole-head beamformer analysis compared to a half-head analysis using only sensors from the hemisphere contralateral to stimulation. Event-related beamformer localisations were also compared with more traditional single-dipole models. At the group level, the event-related beamformer performed equally well as the single-dipole models in terms of accuracy for both the N1m and the P2m, and in terms of efficiency (number of successful source models) for the N1m. The results yielded by the half-head analysis did not differ significantly from those produced by the traditional whole-head analysis. Any localisation bias caused by the presence of correlated sources is minimal in the context of the inter-individual variability in source localisations. In conclusion, event-related beamformers provide a useful alternative to equivalent-current dipole models in localisation of auditory evoked responses.

References
1.
Yvert B, Fischer C, Bertrand O, Pernier J . Localization of human supratemporal auditory areas from intracerebral auditory evoked potentials using distributed source models. Neuroimage. 2005; 28(1):140-53. DOI: 10.1016/j.neuroimage.2005.05.056. View

2.
Hadjipapas A, Hillebrand A, Holliday I, Singh K, Barnes G . Assessing interactions of linear and nonlinear neuronal sources using MEG beamformers: a proof of concept. Clin Neurophysiol. 2005; 116(6):1300-13. DOI: 10.1016/j.clinph.2005.01.014. View

3.
Ross B, Herdman A, Pantev C . Right hemispheric laterality of human 40 Hz auditory steady-state responses. Cereb Cortex. 2005; 15(12):2029-39. DOI: 10.1093/cercor/bhi078. View

4.
Huang M, Mosher J, Leahy R . A sensor-weighted overlapping-sphere head model and exhaustive head model comparison for MEG. Phys Med Biol. 1999; 44(2):423-40. DOI: 10.1088/0031-9155/44/2/010. View

5.
Pantev C, Ross B, Berg P, Elbert T, Rockstroh B . Study of the human auditory cortices using a whole-head magnetometer: left vs. right hemisphere and ipsilateral vs. contralateral stimulation. Audiol Neurootol. 1998; 3(2-3):183-90. DOI: 10.1159/000013789. View