Optimisation of Image Reconstruction for Phase-contrast X-ray Talbot-Lau Imaging with Regard to Mechanical Robustness
Overview
Nuclear Medicine
Radiology
Affiliations
X-ray grating-based phase-contrast imaging opens new opportunities, inter alia, in medical imaging and non-destructive testing. Because, information about the attenuation properties and about the refractive properties of an object are gained simultaneously. Talbot-Lau imaging requires the knowledge of a reference or free-field image. The long-term stability of a Talbot-Lau interferometer is related to the time span of the validity of a measured reference image. It would be desirable to keep the validity of the reference image for a day or longer to improve feasibility of Talbot-Lau imaging. However, for example thermal and other long-term external influences result in drifting effects of the phase images. Therefore, phases are shifting over time and the reference image is not valid for long-term measurements. Thus, artifacts occur in differential phase-contrast images. We developed an algorithm to determine the differential phase-contrast image with the help of just one calibration image, which is valid for a long time-period. With the help of this algorithm, called phase-plane-fit method, it is possible to save measurement-time, as it is not necessary to take a reference image for each measurement. Additionally, transferring the interferometer technique from laboratory setups to conventional imaging systems the necessary rigidity of the system is difficult to achieve. Therefore, short-term effects like vibrations or distortions of the system lead to imperfections within the phase-stepping procedure. Consequently, artifacts occur in all three image modalities (differential phase-contrast image, attenuation image and dark-field image) of Talbot-Lau imaging. This is a problem with regard to the intended use of phase-contrast imaging for example in clinical routine or non-destructive testing. In this publication an algorithm of Vargas et al is applied and complemented to correct inaccurate phase-step positions with the help of a principal component analysis (PCA). Thus, it is possible to calculate the artifact free images. Subsequently, the whole algorithm is called PCA minimization algorithm.
Dark-field computed tomography reaches the human scale.
Viermetz M, Gustschin N, Schmid C, Haeusele J, von Teuffenbach M, Meyer P Proc Natl Acad Sci U S A. 2022; 119(8).
PMID: 35131900 PMC: 8872773. DOI: 10.1073/pnas.2118799119.
Pinzek S, Gustschin A, Neuwirth T, Backs A, Schulz M, Herzen J J Imaging. 2021; 7(10).
PMID: 34677295 PMC: 8538536. DOI: 10.3390/jimaging7100209.
Birnbacher L, Braig E, Pfeiffer D, Pfeiffer F, Herzen J Eur J Nucl Med Mol Imaging. 2021; 48(13):4171-4188.
PMID: 33846846 PMC: 8566444. DOI: 10.1007/s00259-021-05259-6.
X-ray Phase Contrast osteo-articular imaging: a pilot study on cadaveric human hands.
Rouge-Labriet H, Berujon S, Mathieu H, Bohic S, Fayard B, Ravey J Sci Rep. 2020; 10(1):1911.
PMID: 32024864 PMC: 7002527. DOI: 10.1038/s41598-020-58168-3.
Talbot-Lau x-ray phase-contrast setup for fast scanning of large samples.
Seifert M, Ludwig V, Kaeppler S, Horn F, Meyer P, Pelzer G Sci Rep. 2019; 9(1):4199.
PMID: 30862865 PMC: 6414610. DOI: 10.1038/s41598-018-38030-3.