» Articles » PMID: 27512280

Validity and Reliability of Isometric Muscle Strength Measurements of Hip Abduction and Abduction with External Hip Rotation in a Bent-hip Position Using a Handheld Dynamometer with a Belt

Overview
Journal J Phys Ther Sci
Date 2016 Aug 12
PMID 27512280
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

[Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subjects' right legs was measured under two posture positions using two devices: a handheld dynamometer with a belt and an isokinetic dynamometer. Reliability was evaluated using an intra-class correlation coefficient (ICC); relatedness and validity were evaluated using Pearson's product moment correlation coefficient. Differences in measurements of devices were assessed by two-way ANOVA. [Results] ICC (1, 1) was ≥0.9; significant positive correlations in measurements were found between the two devices under both conditions. No main effect was found between the measurement values. [Conclusion] Our findings revealed that there was relatedness, reliability, and validity of this method for isometric muscle strength measurements using a handheld dynamometer with a belt.

Citing Articles

Isometric Force-Time Curve Assessment: Accuracy, Precision, and Repeatability of a Mobile Application and Portable and Lightweight Device.

Santos D, Bravo-Sanchez A, Peyre-Tartaruga L, Simini F, Zacca R Sports (Basel). 2024; 12(10).

PMID: 39453234 PMC: 11511426. DOI: 10.3390/sports12100268.


A Comparison of Different Strength Measurement in Taekwondo: Herman Trainer, Manual Tester, and Standing Long Jump.

Boyanmis A, Kesilmis I, Akin M, Yilmaz B, Uslular A, Ocal Y Medicina (Kaunas). 2024; 60(4).

PMID: 38674196 PMC: 11052195. DOI: 10.3390/medicina60040550.


Factors associated with the Single Leg Squat test in female soccer players: a cross-sectional study.

Ressman J, Von Rosen P, Grooten W, Rasmussen-Barr E BMC Sports Sci Med Rehabil. 2024; 16(1):76.

PMID: 38566260 PMC: 10985895. DOI: 10.1186/s13102-024-00853-1.


Reliability of hand-held dynamometer in measuring gluteus medius isometric muscle strength in healthy population.

Soomro R, Karimi H, Gillani S Pak J Med Sci. 2022; 38(5):1238-1242.

PMID: 35799746 PMC: 9247787. DOI: 10.12669/pjms.38.5.5207.


AUTOMA: a wearable device to assess the upper limb muscular activity in patients with neuromuscular disorders.

Milazzo M, Spezzaneve A, Astrea G, Giorgolo F, Tonacci A, Sansone F Acta Myol. 2022; 40(4):143-151.

PMID: 35047754 PMC: 8744014. DOI: 10.36185/2532-1900-057.


References
1.
McBeth J, Earl-Boehm J, Cobb S, Huddleston W . Hip muscle activity during 3 side-lying hip-strengthening exercises in distance runners. J Athl Train. 2012; 47(1):15-23. PMC: 3418110. DOI: 10.4085/1062-6050-47.1.15. View

2.
Paul D, Nassis G, Whiteley R, Marques J, Kenneally D, Chalabi H . Acute responses of soccer match play on hip strength and flexibility measures: potential measure of injury risk. J Sports Sci. 2014; 32(13):1318-23. DOI: 10.1080/02640414.2014.927069. View

3.
Hyde S, Goddard C, Scott O . The myometer: the development of a clinical tool. Physiotherapy. 1983; 69(12):424-7. View

4.
Wiles C, Karni Y . The measurement of muscle strength in patients with peripheral neuromuscular disorders. J Neurol Neurosurg Psychiatry. 1983; 46(11):1006-13. PMC: 491736. DOI: 10.1136/jnnp.46.11.1006. View

5.
Sidorkewicz N, Cambridge E, McGill S . Examining the effects of altering hip orientation on gluteus medius and tensor fascae latae interplay during common non-weight-bearing hip rehabilitation exercises. Clin Biomech (Bristol). 2014; 29(9):971-6. DOI: 10.1016/j.clinbiomech.2014.09.002. View