» Articles » PMID: 27502398

In Vitro and in Vivo Effects of Hemodilution on Kaolin-based Activated Clotting Time Predicted Heparin Requirement Using a Heparin Dose-response Technique

Overview
Journal J Anesth
Specialty Anesthesiology
Date 2016 Aug 10
PMID 27502398
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The heparin dose-response (HDR) technique is based on activated clotting time (ACT) response to a fixed-dose heparin bolus, which varies substantially among patients. It is unclear, however, whether hemodilution-associated reductions in coagulation and anticoagulation factors affect the HDR slope.

Methods: For in vitro hemodilution, aliquots of whole blood from healthy volunteers were diluted 9:1 and 8:2 v/v with normal saline. For in vivo hemodilution, a prospective observational study was performed on 46 patients who underwent elective cardiovascular surgery with or without cardiopulmonary bypass. HDR slope, antithrombin (AT) activity, complete blood count, and other coagulation parameters were compared after induction of anesthesia and after hemodilution with 500 ml of intravenous fluid.

Results: In vitro 10 and 20 % hemodilution significantly increased the HDR slope relative to baseline, reducing the heparin requirement. Hemodilution of heparinized samples significantly prolonged ACT, whereas there was no significant change in non-heparinized blood. The percent changes in fibrinogen and AT activity were significantly greater at 20 % than those of the other coagulation variables. In vivo, hemodilution significantly increased the HDR slope and reduced heparin requirement. The percent change in fibrinogen due to hemodilution was significantly greater than the change in AT activity. Target ACTs of 300 and 450 s were not achieved in 83.3 and 53.8 % of patients, respectively.

Conclusion: In vitro and in vivo hemodilution significantly increased the HDR slope and reduced the requirement for heparin. In vitro, the HDR slope did not change in parallel but became steeper, depending on the degree of hemodilution.

Citing Articles

Can We Rely on the Activated Clotting Time to Measure Heparin Anticoagulation? A Clinical Evaluation of Two ACT Monitors.

Nilsson S, Appelblad M, Svenmarker S J Extra Corpor Technol. 2020; 52(3):212-217.

PMID: 32981959 PMC: 7499231. DOI: 10.1182/ject-2000005.

References
1.
Linden M, Gibbs N, Bremner M, Schneider M, Erber W . The effect of haemodilution on antithrombin concentration during cardiac surgery. Anaesth Intensive Care. 2005; 32(2):219-23. DOI: 10.1177/0310057X0403200209. View

2.
Olson S, BJORK I, Sheffer R, Craig P, SHORE J, CHOAY J . Role of the antithrombin-binding pentasaccharide in heparin acceleration of antithrombin-proteinase reactions. Resolution of the antithrombin conformational change contribution to heparin rate enhancement. J Biol Chem. 1992; 267(18):12528-38. View

3.
MURANO G, Williams L, Aronson D, King C . Some properties of antithrombin-III and its concentration in human plasma. Thromb Res. 1980; 18(1-2):259-62. DOI: 10.1016/0049-3848(80)90190-5. View

4.
Tollefsen D, Majerus D, Blank M . Heparin cofactor II. Purification and properties of a heparin-dependent inhibitor of thrombin in human plasma. J Biol Chem. 1982; 257(5):2162-9. View

5.
Huyzen R, Harder M, Huet R, Boonstra P, Brenken U, van Oeveren W . Alternative perioperative anticoagulation monitoring during cardiopulmonary bypass in aprotinin-treated patients. J Cardiothorac Vasc Anesth. 1994; 8(2):153-6. DOI: 10.1016/1053-0770(94)90054-x. View