Background: Clinical decision support systems, including electronic alerts, ideally provide immediate and relevant patient-specific information to improve clinical decision-making. Despite the growing capabilities of such alerts in conjunction with an expanding electronic medical record, there is a paucity of information regarding their perceived usefulness. We surveyed healthcare providers' opinions concerning the practicality and efficacy of a specific text-based automated electronic alert for acute kidney injury (AKI) in a single hospital during a randomized trial of AKI alerts.

Methods: Providers who had received at least one electronic AKI alert in the previous 6 months, as part of a separate randomized controlled trial (clinicaltrials.gov #01862419), were asked to complete a survey concerning their opinions about this specific AKI alert system. Individual approval of the alert system was defined by a provider's desire to continue receiving the alert after termination of the trial.

Results: A total of 98 individuals completed the survey, including 62 physicians, 27 pharmacists and 7 non-physician providers. Sixty-nine percent of responders approved the alert, with no significant difference among the various professions (P = 0.28). Alert approval was strongly correlated with the belief that the alerts improved patient care (P < 0.0001), and negatively correlated with the belief that alerts did not provide novel information (P = 0.0001). With each additional 30 days of trial duration, odds of approval decreased by 20% (3-35%) (P = 0.02).

Conclusions: The alert system was generally well received, although approval waned with time. Approval was correlated with the belief that this type of alert improved patient care. These findings suggest that perceived efficacy is critical to the success of future alert trials.

Citing Articles

Effect of Tiered Implementation of Clinical Decision Support System for Acute Kidney Injury and Nephrotoxin Exposure in Cardiac Surgery Patients.

Justice 2nd C, Nevin C, Neely R, Dilcher B, Kovacic-Scherrer N, Carter-Templeton H Appl Clin Inform. 2025; 16(1):1-10.

PMID: 39742871 PMC: 11693401. DOI: 10.1055/s-0044-1791822.


An integrative review on the acceptance of artificial intelligence among healthcare professionals in hospitals.

Lambert S, Madi M, Sopka S, Lenes A, Stange H, Buszello C NPJ Digit Med. 2023; 6(1):111.

PMID: 37301946 PMC: 10257646. DOI: 10.1038/s41746-023-00852-5.


Acceptance of Acute Kidney Injury Alert by Providers in Cardiac Surgery Intensive Care Unit.

Nevin C, Shawwa K, Pincavitch J, Neely R, Goodwin D, McCarthy P Appl Clin Inform. 2022; 14(1):119-127.

PMID: 36535704 PMC: 9908418. DOI: 10.1055/a-2000-7499.


Acute kidney injury electronic alerts: mixed methods Normalisation Process Theory evaluation of their implementation into secondary care in England.

Scott J, Finch T, Bevan M, Maniatopoulos G, Gibbins C, Yates B BMJ Open. 2019; 9(12):e032925.

PMID: 31831546 PMC: 6924771. DOI: 10.1136/bmjopen-2019-032925.


eHealth interventions for people with chronic kidney disease.

Stevenson J, Campbell Z, Webster A, Chow C, Tong A, Craig J Cochrane Database Syst Rev. 2019; 8:CD012379.

PMID: 31425608 PMC: 6699665. DOI: 10.1002/14651858.CD012379.pub2.


References
1.
Porter C, Juurlink I, Bisset L, Bavakunji R, Mehta R, Devonald M . A real-time electronic alert to improve detection of acute kidney injury in a large teaching hospital. Nephrol Dial Transplant. 2014; 29(10):1888-93. DOI: 10.1093/ndt/gfu082. View

2.
Colpaert K, Hoste E, Steurbaut K, Benoit D, Van Hoecke S, De Turck F . Impact of real-time electronic alerting of acute kidney injury on therapeutic intervention and progression of RIFLE class. Crit Care Med. 2011; 40(4):1164-70. DOI: 10.1097/CCM.0b013e3182387a6b. View

3.
van der Sijs H, Aarts J, van Gelder T, Berg M, Vulto A . Turning off frequently overridden drug alerts: limited opportunities for doing it safely. J Am Med Inform Assoc. 2008; 15(4):439-48. PMC: 2442265. DOI: 10.1197/jamia.M2311. View

4.
Kuperman G, Teich J, Tanasijevic M, Maluf N, Rittenberg E, Jha A . Improving response to critical laboratory results with automation: results of a randomized controlled trial. J Am Med Inform Assoc. 1999; 6(6):512-22. PMC: 61393. DOI: 10.1136/jamia.1999.0060512. View

5.
Wilson F, Shashaty M, Testani J, Aqeel I, Borovskiy Y, Ellenberg S . Automated, electronic alerts for acute kidney injury: a single-blind, parallel-group, randomised controlled trial. Lancet. 2015; 385(9981):1966-74. PMC: 4475457. DOI: 10.1016/S0140-6736(15)60266-5. View