» Articles » PMID: 27467904

Do Not Burn Your Airway Bridge: A Technique to Safely Exchange a Tracheostomy Tube for a Tracheal Tube

Overview
Journal A A Case Rep
Specialty Anesthesiology
Date 2016 Jul 29
PMID 27467904
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Tracheostomy is one of the most ancient and commonly performed surgical procedures. When tracheostomized patients require a subsequent intervention, it is usually necessary to exchange the tracheostomy tube for a tracheal tube, which can be dangerous. These potential complications may be overlooked or underestimated by the anesthesia providers. An inability to ventilate the patient and replace the tube after removal of a fresh tracheostomy tube can escalate rapidly to a life-threatening crisis. We present a case in which an airway exchange catheter was used to safely replace a tracheostomy tube with a tracheal tube in a patient with a fresh tracheostomy.

Citing Articles

Pilot line damage at the embedded part of a sutured endotracheal tube intubated via a tracheostomy stoma.

Nakanishi T, Sobue K Saudi J Anaesth. 2021; 15(1):79-80.

PMID: 33824654 PMC: 8016050. DOI: 10.4103/sja.SJA_830_20.