» Articles » PMID: 27463550

Effects of Size and Location of Regions of Interest Examined by Use of Contrast-enhanced Ultrasonography on Renal Perfusion Variables of Dogs

Overview
Journal Am J Vet Res
Date 2016 Jul 28
PMID 27463550
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

OBJECTIVE To determine effects of the size and location of regions of interest (ROIs) in the renal cortex of unsedated dogs on renal perfusion variables determined by use of contrast-enhanced ultrasonography (CEUS). ANIMALS 12 client-owned adult (1.5 to 2 years old) Labrador Retrievers (8 males and 4 females; mean ± SD body weight, 27 ± 1.6 kg). PROCEDURES Each dog received 2 bolus injections of sulfur hexafluoride during CEUS. Three small oval ROIs (area of each ROI, 0.11 cm(2)) located in a row with a distance of 1 mm between adjacent ROIs and 1 large oval ROI (area, 1 cm(2)) that encompassed the 3 smaller ROIs were manually drawn in the renal cortex. The ROIs were located at a depth of 1.5 to 2.0 cm in the near field of the renal cortex. Software analysis of time-intensity curves within each ROI was used to identify peak enhancement, time to peak enhancement, regional blood flow, and mean transit time. RESULTS The location and size of the ROIs of unsedated dogs did not cause significant differences in the mean values of the renal perfusion variables. CONCLUSIONS AND CLINICAL RELEVANCE The development of CEUS has provided a unique means for visually examining and quantifying tissue perfusion. Results of this study indicated that it was possible to use small or large ROIs during renal CEUS to evaluate renal perfusion in dogs.

Citing Articles

Renal medullary perfusion differs from that in renal cortex in patients with sepsis associated acute kidney injury and correlates with renal function prognosis: A prospective cohort study.

Chen R, Liu D, Zhao H, Wang X Clin Hemorheol Microcirc. 2024; 88(2):181-198.

PMID: 39121113 PMC: 11492038. DOI: 10.3233/CH-242296.


Ultrasonographic assessment of renal microcirculation is a new vision for the treatment of intensive care unit associated acute kidney injury.

Chen R, Gao B, Wang X, Zhao H, Wang X, Liu D Eur J Med Res. 2024; 29(1):115.

PMID: 38341556 PMC: 10858548. DOI: 10.1186/s40001-024-01704-y.


Intra- and Inter-Observer Variability of Quantitative Parameters Used in Contrast-Enhanced Ultrasound of Kidneys of Healthy Cats.

Hillaert A, Stock E, Favril S, Duchateau L, Saunders J, Vanderperren K Animals (Basel). 2022; 12(24).

PMID: 36552476 PMC: 9774712. DOI: 10.3390/ani12243557.


Feasibility of contrast-enhanced ultrasonography (CEUS) in evaluating renal microvascular perfusion in pediatric patients.

Zhang W, Yi H, Cai B, He Y, Huang S, Zhang Y BMC Med Imaging. 2022; 22(1):194.

PMID: 36357841 PMC: 9650893. DOI: 10.1186/s12880-022-00925-z.


Use of Contrast-Enhanced Ultrasound of the Testes after Non-Surgical Sterilization of Male Dogs with CaCl in Alcohol.

Cicirelli V, Macri F, Di Pietro S, Leoci R, Lacalandra G, Aiudi G Animals (Basel). 2022; 12(5).

PMID: 35268146 PMC: 8909176. DOI: 10.3390/ani12050577.